Back to Search Start Over

Flexing a standard hinge-powered operating table for lumbosacral three-column osteotomy (3-CO) site closure in 84 consecutive patients.

Authors :
Girod, Pierre-Pascal
Kögl, Nikolaus
Molliqaj, Granit
Lener, Sara
Hartmann, Sebastian
Thomé, Claudius
Source :
Neurosurgical Review; Feb2022, Vol. 45 Issue 1, p517-524, 8p
Publication Year :
2022

Abstract

Three-column osteotomy (3-CO) is a powerful technique in adult deformity surgery, and pedicle subtraction osteotomy (PSO) is the workhorse to correct severe kyphotic spinal deformities. Aging of the population, increasing cases of iatrogenic flat back deformities and understanding the importance of sagittal balance have led to a dramatic increase of this surgical technique. Surgery, however, is demanding and associated with high complication rates so that every step of the procedure requires meticulous technique. Particularly, osteotomy closure is associated with risks like secondary fracture, translation, or iatrogenic stenosis. This step is traditionally performed by compression or a cantilever maneuver with sometimes excessive forces on the screws or instrumentation. Implant loosening or abrupt subluxation resulting in construct failure and/or neurological deficits can result. The aim of this prospective registry study was to assess the efficacy and safety of our surgical PSO technique as well as the osteotomy closure by flexing a hinge-powered OR table. In a series of 84 consecutive lumbosacral 3-CO, a standardized surgical technique with special focus on closure of the osteotomy was prospectively evaluated. The surgical steps with the patients positioned prone on a soft frame are detailed. Osteotomy closure was achieved by remote controlled bending of a standard OR table without compressive or cantilever forces in all 84 cases. This technique carries a number of advantages, particularly the reversibility and the slow speed of closure with minimum force. There was not a single mechanical intraoperative complication such as vertebral body fracture, subluxation, or adjacent implant loosening during osteotomy closure, compared to external cohorts using the cantilever technique (p = 0.130). The feasibility of controlled 3-CO closure by flexing a standard OR table is demonstrated. This technique enables a safe, gentle closure of the osteotomy site with minimal risk of implant failure or accidental neurological injury. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03445607
Volume :
45
Issue :
1
Database :
Complementary Index
Journal :
Neurosurgical Review
Publication Type :
Academic Journal
Accession number :
155152858
Full Text :
https://doi.org/10.1007/s10143-021-01559-5