Back to Search Start Over

Trueness of Intraoral Scanners in Implant-Supported Rehabilitations: An In Vitro Analysis on the Effect of Operators' Experience and Implant Number.

Authors :
Pesce, Paolo
Bagnasco, Francesco
Pancini, Nicolò
Colombo, Marco
Canullo, Luigi
Pera, Francesco
Bressan, Eriberto
Annunziata, Marco
Menini, Maria
Source :
Journal of Clinical Medicine; Dec2021, Vol. 10 Issue 24, p5917-5917, 1p
Publication Year :
2021

Abstract

(1) Background: Intraoral scanners (IOS) are widely used in prosthodontics. However, a good trueness is mandatory to achieve optimal clinical results. The aim of the present in vitro study was to compare two IOS considering the operator's experience and different implant clinical scenarios. (2) Methods: Two IOS (IT—Itero, Align Technology; and OP—Opera MC, Opera System, Monaco) were compared simulating three different clinical scenarios: single implant, two implants, and full-arch rehabilitation. Ten scans were taken for each configuration by two different operators (one expert, one inexperienced); influence of operator experience and the type of scanner used was investigated. (3) Results: Trueness of the scans differed between the experienced and non-experienced operator and this difference was statistically significant in all the three scenarios (p = 0.000–0.001, 0.037). A significant difference was present between the scanners (p = 0.000), in the two-implant and full-arch scenarios (p = 0.00). (4) Conclusions: Experience of the operator significantly affect trueness of IT and OP scanners. A statistically significant difference was present among IOS in the two-implant and full-arch scenarios. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20770383
Volume :
10
Issue :
24
Database :
Complementary Index
Journal :
Journal of Clinical Medicine
Publication Type :
Academic Journal
Accession number :
154367382
Full Text :
https://doi.org/10.3390/jcm10245917