Back to Search Start Over

Fusion Visualization Technique to Improve a Three-Dimensional Isotope-Selective CT Image Based on Nuclear Resonance Fluorescence with a Gamma-CT Image.

Authors :
Ali, Khaled
Zen, Heishun
Ohgaki, Hideaki
Kii, Toshiteru
Hayakawa, Takehito
Shizuma, Toshiyuki
Katoh, Masahiro
Taira, Yoshitaka
Fujimoto, Masaki
Toyokawa, Hiroyuki
Source :
Applied Sciences (2076-3417); Dec2021, Vol. 11 Issue 24, p11866, 17p
Publication Year :
2021

Abstract

One of the most noteworthy aspects of computed tomography (CT) based on the nuclear resonance fluorescence (NRF) transmission method is the isotope selectivity that makes it possible to discern an isotope of interest from other isotopes within a sample. We experimentally obtained a three-dimensional (3D) isotope-selective CT image based on the NRF transmission method (3D NRF-CT) for the enriched lead isotope distribution of <superscript>208</superscript>Pb in a cylindrical holder in a previous study. The cylindrical holder's diameter and height are 25 mm and 20 mm, respectively. The NRF-CT imaging technique requires a considerable data accumulation time. It took 48 h to obtain an image with a resolution of 4 mm/pixel in the horizontal plane and 8 mm/pixel in the vertical plane using a laser Compton scattering (LCS) gamma-ray beam with a beam size of 2 mm and a flux density of 10 photons/s/eV. Improving the NRF-CT image resolution with the existing hardware is challenging. Therefore, we proposed an alternative method to improve the NRF-CT image resolution using the fusion visualization (FV) technique by combining the NRF-CT image including isotopic information with a gamma-CT image, which provides better pixel resolution. The 3D gamma-CT image for the same sample was measured at the same beamline BL1U in the ultraviolet synchrotron orbital radiation-III (UVSOR-III) synchrotron radiation facility at the Institute of Molecular Science at the National Institutes of Natural Sciences in Japan under similar experimental conditions except for the LCS gamma-ray beam flux and beam size. Obtaining a 3D gamma-CT image with a resolution of 1 mm/pixel took 5 h using an LCS gamma-ray beam with a beam size of 1 mm and a flux density of 0.7 photons/s/eV. The data processing of the FV technique has been developed, and the 3D NRF-CT image quality was improved. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20763417
Volume :
11
Issue :
24
Database :
Complementary Index
Journal :
Applied Sciences (2076-3417)
Publication Type :
Academic Journal
Accession number :
154316523
Full Text :
https://doi.org/10.3390/app112411866