Back to Search Start Over

Comparison of V̇O2-Kinetic Parameters for the Management of Heart Failure.

Authors :
Wagner, Jonathan
Niemeyer, Max
Infanger, Denis
Pfister, Otmar
Myers, Jonathan
Schmidt-Trucksäss, Arno
Knaier, Raphael
Source :
Frontiers in Physiology; 11/25/2021, Vol. 12, p1-11, 11p
Publication Year :
2021

Abstract

Objective: The aim of this study was to analyze whether V̇O<subscript>2</subscript>-kinetics during cardiopulmonary exercise testing (CPET) is a useful marker for the diagnosis of heart failure (HF) and to determine which V̇O<subscript>2</subscript>-kinetic parameter distinguishes healthy participants and patients with HF. Methods: A total of 526 healthy participants and 79 patients with HF between 20 and 90 years of age performed a CPET. The CPET was preceded by a 3-min low-intensity warm-up and followed by a 3-min recovery bout. V̇O<subscript>2</subscript>-kinetics was calculated from the rest to exercise transition of the warm-up bout (on-kinetics), from the exercise to recovery transition following ramp test termination (off-kinetics) and from the initial delay of V̇O<subscript>2</subscript> during the warm-up to ramp test transition (ramp-kinetics). Results: V̇O<subscript>2</subscript> off-kinetics showed the highest z -score differences between healthy participants and patients with HF. Furthermore, off-kinetics was strongly associated with V̇O<subscript>2peak</subscript>. In contrast, ramp-kinetics and on-kinetics showed only minimal z -score differences between healthy participants and patients with HF. The best on- and off-kinetic parameters significantly improved a model to predict the disease severity. However, there was no relevant additional value of V̇O<subscript>2</subscript>-kinetics when V̇O<subscript>2peak</subscript> was part of the model. Conclusion: V̇O<subscript>2</subscript> off-kinetics appears to be superior for distinguishing patients with HF and healthy participants compared with V̇O<subscript>2</subscript> on-kinetics and ramp-kinetics. If V̇O<subscript>2peak</subscript> cannot be determined, V̇O<subscript>2</subscript> off-kinetics provides an acceptable substitute. However, the additional value beyond that of V̇O<subscript>2peak</subscript> cannot be provided by V̇O<subscript>2</subscript>-kinetics. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
1664042X
Volume :
12
Database :
Complementary Index
Journal :
Frontiers in Physiology
Publication Type :
Academic Journal
Accession number :
153798989
Full Text :
https://doi.org/10.3389/fphys.2021.775601