Abstract

Simple Summary: Gleason grading of prostate cancer is essential for treatment strategies and patient prognosis. Previous studies showed grading variation between pathologists when grading prostate cancer. Our study analyzed the presence and extent of grading variation between and within pathology laboratories in The Netherlands. In our nationwide retrospective study, we analyzed prostate needle biopsy reports of 35,258 patients in The Netherlands graded by 40 pathology laboratories. We found a considerable variation between and within pathology laboratories, as over half of the laboratories graded significantly different from the national mean. This likely affects treatment strategy and prognosis assessment of prostate cancer patients. Purpose: Our aim was to analyze grading variation between pathology laboratories and between pathologists within individual laboratories using nationwide real-life data. Methods: We retrieved synoptic (n = 13,397) and narrative (n = 29,377) needle biopsy reports from the Dutch Pathology Registry and prostate-specific antigen values from The Netherlands Cancer Registration for prostate cancer patients diagnosed between January 2017 and December 2019. We determined laboratory-specific proportions per histologic grade and unadjusted odds ratios (ORs) for International Society of Urological Pathologists Grades 1 vs. 2–5 for 40 laboratories due to treatment implications for higher grades. Pathologist-specific proportions were determined for 21 laboratories that consented to this part of analysis. The synoptic reports of 21 laboratories were used for analysis of case-mix correction for PSA, age, year of diagnosis, number of biopsies and positive cores. Results: A total of 38,321 reports of 35,258 patients were included. Grade 1 ranged between 19.7% and 44.3% per laboratory (national mean = 34.1%). Out of 40 laboratories, 22 (55%) reported a significantly deviant OR, ranging from 0.48 (95% confidence interval (CI) 0.39–0.59) to 1.54 (CI 1.22–1.93). Case-mix correction was performed for 10,294 reports, altering the status of 3/21 (14%) laboratories, but increasing the observed variation (20.8% vs. 17.7%). Within 15/21 (71%) of laboratories, significant inter-pathologist variation existed. Conclusion: Substantial variation in prostate cancer grading was observed between and within Dutch pathology laboratories. Case-mix correction did not explain the variation. Better standardization of prostate cancer grading is warranted to optimize and harmonize treatment. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20726694
Volume :
13
Issue :
21
Database :
Complementary Index
Journal :
Cancers
Publication Type :
Academic Journal
Accession number :
153602560
Full Text :
https://doi.org/10.3390/cancers13215378