Quantitative extraction of chromium VI and III from tanned leather: a comparative study of pretreatment methods.

Authors :
Arellano-Sánchez, Mónica Gisel
Devouge-Boyer, Christine
Hubert-Roux, Marie
Afonso, Carlos
Mignot, Mélanie
Source :
Journal of Leather Science & Engineering; 11/15/2021, Vol. 3 Issue 1, p1-13, 13p
Publication Year :
2021

Abstract

In this study, seven pretreatment methods for chromium speciation in tanned leather were evaluated: acidic mineralization, ethylenediaminetetraacetic acid (EDTA) extraction, diethylenetriaminepentaacetic acid (DTPA) extraction, alkaline extraction (NH<subscript>4</subscript>OH), ammonium nitrate extraction (NH<subscript>4</subscript>NO<subscript>3</subscript>), water extraction, and phosphate buffer extraction. Acidic mineralization permitted the decomposition of the organic matter and ensured the complete digestion of leathers, giving access to the total content of chromium in each sample using inductively coupled plasma-atomic emission spectrometry (ICP-AES). From all the extractant media tested, EDTA proved to be the most efficient, allowing the extraction of Cr(VI) and Cr(III) as a Cr(III)-EDTA complex, quantitatively. Method validation is presented for EDTA extraction and direct mineralization. For the EDTA extraction, method detection limit (MDL) and method quantification limit (MQL) for total Cr in leather were 3.4 ppb and 11.2 ppb (µg of total Cr per L of extraction solution), respectively. Due to the lack of leather certified reference materials (CRMs) for Cr(VI), accuracy was evaluated by spiking leather samples with a Cr(VI) solution. The spike recovery of EDTA microwave assisted extraction ranged from 91.0 to 108.6%. Interday precision was also evaluated and all variation coefficients were below 5%, for both mineralization and EDTA extraction. This article provides an efficient procedure to extract quantitatively chromium from leather, while maintaining the speciation, which can be further followed by ion chromatography-inductively coupled plasma-mass spectrometry (IC-ICP-MS). [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
25247859
Volume :
3
Issue :
1
Database :
Complementary Index
Journal :
Journal of Leather Science & Engineering
Publication Type :
Academic Journal
Accession number :
153555759
Full Text :
https://doi.org/10.1186/s42825-021-00071-2