Back to Search Start Over

Incremental diagnostic value of color-coded virtual non-calcium dual-energy CT for the assessment of traumatic bone marrow edema of the scaphoid.

Authors :
Koch, Vitali
Müller, Felix Christoph
Gosvig, Kasper
Albrecht, Moritz H.
Yel, Ibrahim
Lenga, Lukas
Martin, Simon S.
Cavallaro, Marco
Wichmann, Julian L.
Mader, Christoph
D'Angelo, Tommaso
Mazziotti, Silvio
Cicero, Giuseppe
Vogl, Thomas J.
Booz, Christian
Source :
European Radiology; Jul2021, Vol. 31 Issue 7, p4428-4437, 10p, 2 Color Photographs, 1 Diagram, 4 Charts, 3 Graphs
Publication Year :
2021

Abstract

Objectives: To investigate the diagnostic accuracy of color-coded dual-energy CT virtual non-calcium (VNCa) reconstructions for the assessment of bone marrow edema (BME) of the scaphoid in patients with acute wrist trauma. Methods: Our retrospective study included data from 141 patients (67 women, 74 men; mean age 43 years, range 19–80 years) with acute wrist trauma who had undergone third-generation dual-source dual-energy CT and 3-T MRI within 7 days. Eight weeks after assessment of conventional grayscale dual-energy CT scans for the presence of fractures, corresponding color-coded VNCa reconstructions were independently analyzed by the same six radiologists for the presence of BME. CT numbers on VNCa reconstructions were evaluated by a seventh radiologist. Consensus reading of MRI series by two additional radiologists served as the reference standard. Results: MRI depicted 103 scaphoideal zones with BME in 76 patients. On qualitative analysis, VNCa images yielded high overall sensitivity (580/618 [94%]), specificity (1880/1920 [98%]), and accuracy (2460/2538 [97%]) for assessing BME as compared with MRI as reference standard. The interobserver agreement was excellent (κ = 0.98). CT numbers derived from VNCa images were significantly different in zones with and without edema (p < 0.001). A cutoff value of – 46 Hounsfield units provided a sensitivity of 91% and specificity of 97% for differentiating edematous scaphoid lesions. Receiver operating characteristic curve analysis revealed an overall area under the curve of 0.98. Conclusions: Qualitative and quantitative analyses showed excellent diagnostic accuracy of color-coded VNCa reconstructions for assessing traumatic BME of the scaphoid compared to MRI. Key Points: • Color-coded virtual non-calcium (VNCa) reconstructions yield excellent diagnostic accuracy in assessing bone marrow edema of the scaphoid. • VNCa imaging enables detection of non-displaced fractures that are occult on standard grayscale CT. • Diagnostic confidence is comparable between VNCa imaging and MRI. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09387994
Volume :
31
Issue :
7
Database :
Complementary Index
Journal :
European Radiology
Publication Type :
Academic Journal
Accession number :
150974478
Full Text :
https://doi.org/10.1007/s00330-020-07541-x