Back to Search Start Over

Characterization of extracellular vesicles and synthetic nanoparticles with four orthogonal single‐particle analysis platforms.

Authors :
Arab, Tanina
Mallick, Emily R.
Huang, Yiyao
Dong, Liang
Liao, Zhaohao
Zhao, Zezhou
Gololobova, Olesia
Smith, Barbara
Haughey, Norman J.
Pienta, Kenneth J.
Slusher, Barbara S.
Tarwater, Patrick M.
Tosar, Juan Pablo
Zivkovic, Angela M.
Vreeland, Wyatt N.
Paulaitis, Michael E.
Witwer, Kenneth W.
Source :
Journal of Extracellular Vesicles; Apr2021, Vol. 10 Issue 6, p1-20, 20p
Publication Year :
2021

Abstract

We compared four orthogonal technologies for sizing, counting, and phenotyping of extracellular vesicles (EVs) and synthetic particles. The platforms were: single‐particle interferometric reflectance imaging sensing (SP‐IRIS) with fluorescence, nanoparticle tracking analysis (NTA) with fluorescence, microfluidic resistive pulse sensing (MRPS), and nanoflow cytometry measurement (NFCM). EVs from the human T lymphocyte line H9 (high CD81, low CD63) and the promonocytic line U937 (low CD81, high CD63) were separated from culture conditioned medium (CCM) by differential ultracentrifugation (dUC) or a combination of ultrafiltration (UF) and size exclusion chromatography (SEC) and characterized by transmission electron microscopy (TEM) and Western blot (WB). Mixtures of synthetic particles (silica and polystyrene spheres) with known sizes and/or concentrations were also tested. MRPS and NFCM returned similar particle counts, while NTA detected counts approximately one order of magnitude lower for EVs, but not for synthetic particles. SP‐IRIS events could not be used to estimate particle concentrations. For sizing, SP‐IRIS, MRPS, and NFCM returned similar size profiles, with smaller sizes predominating (per power law distribution), but with sensitivity typically dropping off below diameters of 60 nm. NTA detected a population of particles with a mode diameter greater than 100 nm. Additionally, SP‐IRIS, MRPS, and NFCM were able to identify at least three of four distinct size populations in a mixture of silica or polystyrene nanoparticles. Finally, for tetraspanin phenotyping, the SP‐IRIS platform in fluorescence mode was able to detect at least two markers on the same particle, while NFCM detected either CD81 or CD63. Based on the results of this study, we can draw conclusions about existing single‐particle analysis capabilities that may be useful for EV biomarker development and mechanistic studies. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20013078
Volume :
10
Issue :
6
Database :
Complementary Index
Journal :
Journal of Extracellular Vesicles
Publication Type :
Academic Journal
Accession number :
150003164
Full Text :
https://doi.org/10.1002/jev2.12079