A 3-kW Two-Stage Transformerless PV Inverter With Resonant DC Link and ZVS-PWM Operation.

Authors :
Chen, Yenan
Chen, Minjie
Xu, Dehong
Source :
IEEE Transactions on Industry Applications; Mar/Apr2021, Vol. 57 Issue 2, p1495-1506, 12p
Publication Year :
2021

Abstract

Photovoltaic (PV) inverters play important roles in renewable energy integration. Reducing the switching loss is a main challenge in improving the efficiency and power density. This article presents the design, implementation, and field test of a 3-kW two-stage commercial-ready transformerless PV inverter with resonant dc link and zero-voltage-switching pulsewidth modulation (ZVS-PWM) operation. The ZVS-PWM operation periodically resonates the dc-link voltage of the inverter to zero for ZVS of the inverter switches, which enables higher switching frequency and significantly reduced magnetic component size. A 30-kW distributed PV system comprising ten ZVS-PWM PV inverters was built and tested for more than 100 days to evaluate the long-term performance of the PV inverter. The key figure-of-merits for grid-interface operation, such as efficiency, power density, total harmonic distortion, and leakage current, are measured, analyzed, and reported. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00939994
Volume :
57
Issue :
2
Database :
Complementary Index
Journal :
IEEE Transactions on Industry Applications
Publication Type :
Academic Journal
Accession number :
149510140
Full Text :
https://doi.org/10.1109/TIA.2020.3043218