Assessment of shutdown dose rates at the ESS target cooling system using SCALE6.2.

Authors :
Chambon, Amalia
Klinkby, Esben
Emås, Leif
Lauritzen, Bent
Herwig, Kenneth W.
Iverson, Erik B.
Source :
Journal of Neutron Research; 2020, Vol. 22 Issue 2/3, p309-318, 10p
Publication Year :
2020

Abstract

The production of high-energy neutrons at the European Spallation Source through the spallation process may cause an erosion of the tungsten target. The eroded particles could be released into the target helium cooling system which contains four kind of filters. Among them, the auxiliary filters called "getters" are designed to capture volatile elements and remaining dust. In this work, the ORNL's SCALE6.2 modelling and simulation suite for nuclear safety analysis is applied to assess shutdown dose rates and determine if added shielding and/or robotic arms are needed for their maintenance. SCALE6.2 is well adapted to treat this problem as it allows for isotope selection regarding source term calculation. Dose rates are determined by an ORIGEN2 source term and a MAVRIC shielding sequence calculation. As SCALE6.2 is non-standard software for ESS, the results are verified against MCNP, which is the baseline tool for neutronics analysis at ESS. Dose rate calculations show that additional shielding and/or robot arm are not needed to remove the getters after 3 months of cooling time, following 5400 h of operation at 5 MW beam power. At a distance of 1 mm from the getter, the dose rate is 0.2 mSv/h in the most conservative estimation. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10238166
Volume :
22
Issue :
2/3
Database :
Complementary Index
Journal :
Journal of Neutron Research
Publication Type :
Academic Journal
Accession number :
146528793
Full Text :
https://doi.org/10.3233/JNR-190136