Back to Search Start Over

Evaluation of the Diagnostic Efficacy of Xpert CT/NG for Chlamydia trachomatis and Neisseria gonorrhoeae.

Authors :
Xie, Tian-Ao
Liu, Ye-Ling
Meng, Rui-Chun
Liu, Xiao-Shan
Fang, Ke-Ying
Deng, Shu-Ting
Fan, Shu-Jin
Chen, Chu-Mao
Lin, Qin-Rong
He, Zhi-Jian
Li, Zhen-Xing
Ouyang, Shi
Zhu, Guo-Dong
Ji, Tian-Xing
Xia, Yong
Pan, Zhi-Yong
Guo, Xu-Guang
Source :
BioMed Research International; 10/12/2020, p1-16, 16p
Publication Year :
2020

Abstract

Background. Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) are widely spread across the world. Asymptomatic or inconspicuous CT/NG infections are difficult to diagnose and treat. Traditional methods have the disadvantages of low detection rate, inaccurate results, and long detection time. However, Xpert CT/NG makes up for the aforementioned shortcomings and has research value and popularization significance. Methods. PubMed, Embase, Cochrane Library, and Web of Science were systematically searched, and studies were screened using Xpert CT/NG for diagnosing CT/NG. QUADAS-2 was used to evaluate the quality of the eligible studies. Then, two groups of researchers independently extracted data from these studies. Meta-analyses of sensitivity (SEN), specificity (SPE), positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and the area under the curve (AUC) of the summary receiver operating characteristic (SROC) curve were conducted using Meta-DiSc 1.4. Finally, Deek's funnel plots were made using Stata 12.0 to evaluate publication bias. Results. 14 studies were identified, and 46 fourfold tables were extracted in this meta-analysis. The pooled SEN, SPE, PLR, NLR, DOR, and AUC in diagnosing CT were 0.94 (95% confidence interval (CI): 0.93–0.95), 0.99 (95% CI: 0.99–1.00), 97.17 (95% CI: 56.76–166.32), 0.07 (95% CI: 0.04–0.12), 1857.25 (95% CI: 943.78–3654.86), and 0.9960, respectively. The pooled SEN, SPE, PLR, NLR, DOR, and AUC in diagnosing NG were 0.95 (95% CI: 0.93–0.96), 1.00 (95% CI: 1.00–1.00), 278.15 (95% CI: 152.41–507.63), 0.08 (95% CI: 0.06–0.12), 4290.70 (95% CI: 2161.78–8516.16), and 0.9980, respectively. Conclusions. Xpert CT/NG had high diagnostic sensitivity and specificity for CT and NG. However, more evidence is required to confirm that Xpert CT/NG might serve as the primary method for detecting CT and NG and even the gold standard for diagnosis in the future. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
23146133
Database :
Complementary Index
Journal :
BioMed Research International
Publication Type :
Academic Journal
Accession number :
146393131
Full Text :
https://doi.org/10.1155/2020/2892734