Back to Search Start Over

Drug Tolerant Anti-drug Antibody Assay for Infliximab Treatment in Clinical Practice Identifies Positive Cases Earlier.

Authors :
Kharlamova, Nastya
Hermanrud, Christina
Dunn, Nicky
Ryner, Malin
Hambardzumyan, Karen
Vivar Pomiano, Nancy
Marits, Per
Gjertsson, Inger
Saevarsdottir, Saedis
Pullerits, Rille
Fogdell-Hahn, Anna
Source :
Frontiers in Immunology; 7/21/2020, Vol. 11, p1-16, 16p
Publication Year :
2020

Abstract

A subgroup of patients treated with infliximab lose response to the treatment and one reason for this is the development of anti-drug antibodies (ADA). If used optimally, measuring drug and ADA level could lead to a more personalized and efficient treatment regime, and enable identification of ADA-positive patients before the underlying disease flares or allergic reactions occur. With the use of a drug-tolerant ADA assay which can detect ADA irrespective of drug levels in the sample, we determined the impact of ADA on treatment failure to infliximab. The aims of this study were to estimate the real-life optimal serum infliximab (sIFX) level and set a clinical threshold value for a drug-tolerant ADA assay. Trough levels of sIFX were measured with ELISA. Free ADA was measured with two drug-sensitive methods (ELISA and a bioassay) and one drug-tolerant method (PandA). Two real-life cohorts treated with infliximab were included; a cross-sectional cohort including patients with inflammatory rheumatic diseases (n = 270) and a prospective cohort of rheumatoid arthritis (RA) patients (n = 73) followed for 1 year. Normal range of sIFX was estimated from the prospective cohort and an arbitrary optimal drug level was set to be between 1 and 6 μg/mL. Using this range, optimal sIFX was found in only 60% (163/270) of the patients in the cross-sectional cohort. These patients had significantly better treatment response than those with a drug level under 1 μg/mL, who had an ADA frequency of 34% (19/56) using the drug-tolerant method. In the prospective cohort, the drug-tolerant assay could identify 34% (53/155 samples) as ADA positive in samples with sIFX level >0.2 μg/mL. ADA were seldom detected in patients with >1 μg/mL sIFX, with three interesting exceptions. A clinically relevant ADA threshold was determined to be >3 RECL as measured with the drug-tolerant assay. In a real-life setting, there was a substantial number of patients with suboptimal drug levels and a proportion of these had ADA. Both too low and too high drug levels correlated with worse disease, but for different reasons. Adding a drug-tolerant assay enabled detection of ADA earlier and regardless of drug level at time of sampling. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
16643224
Volume :
11
Database :
Complementary Index
Journal :
Frontiers in Immunology
Publication Type :
Academic Journal
Accession number :
144714434
Full Text :
https://doi.org/10.3389/fimmu.2020.01365