- <bold>Background: </bold>The assessment of organ motion is a crucial feature for prostate stereotactic body radiotherapy (SBRT). Rectal spacer may represent a helpful device in order to outdistance rectal wall from clinical target, but its impact on organ motion is still a matter of debate. MRI-Linac is a new frontier in radiation oncology as it allows a superior visualization of the real-time anatomy of the patient and the current highest level of adaptive radiotherapy.<bold>Methods: </bold>We present data regarding a total of 100 fractions in 20 patients who underwent MRI-guided prostate SBRT for low-to-intermediate risk prostate cancer with or without spacer. Translational and rotational shifts were computed on the pre- and post-treatment MRI acquisitions referring to the delivery position for antero-posterior, latero-lateral and cranio-caudal direction, and assessed using the Mann-Whitney U-Test.<bold>Results: </bold>All patients were treated with a five sessions schedule (35 Gy/5fx) using MRI-Linac for a median fraction treatment time of 50 min (range, 46-65). In the entire study sample, median rotational displacement was 0.1° in cranio-caudal, - 0.002° in latero-lateral and 0.01° in antero-posterior direction; median translational shift was 0.11 mm in cranio-caudal, - 0.24 mm in latero-lateral and - 0.22 mm in antero-posterior. A significant difference between spacer and no-spacer patients in terms of rotational shifts in the antero-posterior direction (p = 0.033) was observed; also for translational shifts a positive trend was detected in antero-posterior direction (p = 0.07), although with no statistical significance. We observed statistically significant differences in the pre-treatment planning phase in favor of the spacer cohort for several rectum dose constraints: rectum V32Gy < 5% (p = 0.001), V28 Gy < 10% (p = 0.001) and V18Gy < 35% (p = 0.039). Also for bladder V35 Gy < 1 cc, the use of spacer provided a dosimetric advantage compared to the no-spacer subpopulation (p = 0.04). Furthermore, PTV V33.2Gy > 95% was higher in the spacer cohort compared to the no-spacer one (p = 0.036).<bold>Conclusion: </bold>In our experience, the application of rectal hydrogel spacer for prostate SBRT resulted in a significant impact on rotational antero-posterior shifts contributing to limit prostate intra-fraction motion. Further studies with larger sample size and longer follow-up are required to confirm this ideally favorable effect and to assess any potential impact on clinical outcomes. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 1748717X
- Volume :
- 15
- Issue :
- 1
- Database :
- Complementary Index
- Journal :
- Radiation Oncology
- Publication Type :
- Academic Journal
- Accession number :
- 144707957
- Full Text :
- https://doi.org/10.1186/s13014-020-01622-3