Back to Search Start Over

Assessing the construct validity and responsiveness of Preference-Based Measures (PBMs) in cataract surgery patients.

Authors :
Breheny, Katie
Hollingworth, William
Kandiyali, Rebecca
Dixon, Padraig
Loose, Abi
Craggs, Pippa
Grzeda, Mariusz
Sparrow, John
Source :
Quality of Life Research; Jul2020, Vol. 29 Issue 7, p1935-1946, 12p, 6 Charts
Publication Year :
2020

Abstract

<bold>Purpose: </bold>The validity and responsiveness of the EQ-5D-3L in visual conditions has been questioned, inspiring development of a vision 'bolt-on' domain (EQ-5D-3L + VIS). Developments in preference-based measures (PBM) also includes the EQ-5D-5L and the ICECAP-O capability wellbeing measure. This study aimed to examine the construct validity and responsiveness of the EQ-5D-3L, EQ-5D-5L, EQ-5D-3L + VIS and ICECAP-O in cataract surgery patients for the first time, to inform choice of PBM for economic evaluation in this population.<bold>Methods: </bold>The analyses used data from the UK Predict-CAT cataract surgery cohort study. PBMs and the Cat-PROM5 [a validated measure of cataract quality of life (QOL)] were completed before surgery and 4-8 weeks after. Construct validity was assessed using correlations and known-group differences evaluated using regression. Responsiveness was evaluated using effect sizes and analysis of variance to compare change scores between groups, defined by patient-reported and clinical outcomes.<bold>Results: </bold>The sample comprised 1315 patients at baseline. No PBMs were associated with visual acuity and only the ICECAP-O (Spearman's rs =  - 0.35), EQ-5D-3L + VIS (rs =  - 0.42) and EQ-5D-5L (Value Set for England rs =  - 0.31) correlated at least moderately with the Cat-PROM5. Effect sizes of change were consistently largest for the EQ-5D-3L + VIS (range 0.34-0.41), followed by the ICECAP-O (range 0.20-0.34). Results indicated no improvement in responsiveness using the EQ-5D-5L (range 0.13-0.16) compared to the EQ-5D-3L (range 0.17-0.20).<bold>Conclusions: </bold>Whilst no PBMs comprehensively demonstrated evidence of construct validity and responsiveness in cataract surgery patients, the ICECAP-O was the most responsive generic PBM to improvements in QOL. Surprisingly the EQ-5D-5L was not more responsive than the EQ-5D-3L in this setting. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09629343
Volume :
29
Issue :
7
Database :
Complementary Index
Journal :
Quality of Life Research
Publication Type :
Academic Journal
Accession number :
143783892
Full Text :
https://doi.org/10.1007/s11136-020-02443-3