Back to Search
Start Over
Single and repeat cervical-length measurement in twin gestation with threatened preterm labor.
- Source :
- Ultrasound in Obstetrics & Gynecology; Apr2020, Vol. 55 Issue 4, p496-501, 6p
- Publication Year :
- 2020
-
Abstract
- <bold>Objective: </bold>To examine the effectiveness of single and repeat sonographic cervical-length (CL) measurement in predicting preterm delivery in symptomatic women with a twin pregnancy.<bold>Methods: </bold>This was a retrospective study of women with a twin gestation who presented with painful and regular uterine contractions at 24 + 0 to 33 + 6 weeks' gestation at the perinatal unit of the University Hospital of Tübingen, Tübingen, Germany between 2012 and 2018. CL was measured on transvaginal ultrasound at the time of admission and a few days later after cessation of contractions. Treatment included administration of tocolytics (usually oral nifedipine), for no more than 48 h, and administration of steroids if CL was ≤ 25 mm. Patients were clustered into five groups according to the CL measurement obtained at first assessment: < 10.0 mm; between 10.0 and 14.9 mm; between 15.0 and 19.9 mm; between 20.0 and 24.9 mm; and ≥ 25.0 mm. For each group, we calculated the test performance of CL measurement for prediction of preterm delivery within the subsequent 7 days and before 34 weeks' gestation. Regression analysis was used to evaluate the test performance of the second CL measurement for predicting preterm delivery within 7 days after the second assessment.<bold>Results: </bold>The study population consisted of 257 twin pregnancies, of which 80.2% were dichorionic diamniotic. Median maternal and gestational ages at the time of admission were 32.0 years and 29.9 weeks' gestation, respectively. Preterm birth within 7 days of admission occurred in 23 (8.9%) pregnancies, and 82 (31.9%) patients delivered prior to 34 weeks' gestation. Median CL for the entire study population was 17.0 mm. Delivery within 7 days after the first assessment occurred in 29.0%, 10.6%, 4.2%, 6.3% and 0% of women with CL < 10.0 mm, 10.0-14.9 mm, 15.0-19.9 mm, 20.0-24.9 mm and ≥ 25.0 mm, respectively. There was a weak, but significant, association between the CL measurement at the time of admission and the time interval between admission and delivery (interval = 27.9 + 0.58 × CL; P = 0.003, r = 0.184). CL was measured again after a median time interval of 3 (interquartile range (IQR), 2-5) days in 248 cases. Median second CL measurement was 17.0 (IQR, 11.5-22.0) mm. Delivery occurred within the subsequent 7 days after the second measurement in 25/248 (10.1%) cases. Binary regression analysis indicated that the first (odds ratio (OR), 0.895; P = 0.003) and second (OR, 0.908; P = 0.002) CL measurements, but not the difference between the two measurements (OR, 0.961; P = 0.361), were associated significantly with delivery within 7 days after the second measurement. Receiver-operating-characteristics (ROC)-curve analysis for the prediction of delivery within 7 days after the second assessment did not show a significant difference between the predictive performance of the first (area under ROC curve (AUC), 0.676 (95% CI, 0.559-0.793)) and the second (AUC, 0.661 (95% CI, 0.531-0.790)) measurement.<bold>Conclusion: </bold>Sonographic measurement of CL can be helpful in predicting preterm delivery within 7 days of presentation in symptomatic women with a twin gestation; however, the test performance is relatively weak. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd. [ABSTRACT FROM AUTHOR]
- Subjects :
- PREMATURE labor
PREGNANCY
UTERINE contraction
MATERNAL age
RECEIVER operating characteristic curves
RESEARCH
PREMATURE infants
PREDICTIVE tests
RESEARCH methodology
REGRESSION analysis
GESTATIONAL age
RETROSPECTIVE studies
MEDICAL cooperation
EVALUATION research
COMPARATIVE studies
RESEARCH funding
ODDS ratio
FETAL ultrasonic imaging
MULTIPLE pregnancy
Subjects
Details
- Language :
- English
- ISSN :
- 09607692
- Volume :
- 55
- Issue :
- 4
- Database :
- Complementary Index
- Journal :
- Ultrasound in Obstetrics & Gynecology
- Publication Type :
- Academic Journal
- Accession number :
- 142500767
- Full Text :
- https://doi.org/10.1002/uog.20306