Back to Search Start Over

Application of Advanced Vibration Monitoring Systems and Long Short-Term Memory Networks for Brushless DC Motor Stator Fault Monitoring and Classification.

Authors :
Zimnickas, Tomas
Vanagas, Jonas
Dambrauskas, Karolis
Kalvaitis, Artūras
Ažubalis, Mindaugas
Source :
Energies (19961073); Feb2020, Vol. 13 Issue 4, p820, 1p, 6 Diagrams, 3 Charts, 7 Graphs
Publication Year :
2020

Abstract

In this research, electric motors faults and their identification is reviewed. Brushless direct-current (BLDC) motors stator fault identification using long short-term memory neural networks were analyzed. A proposed method of vibration data acquisition using cloud technologies with high accuracy, feature extraction using spectral entropy, and instantaneous frequency and standardization using mean and standard deviation was reviewed. Additionally, model training with raw and standardized data was compared. A total model accuracy of 97.10 percent was achieved. The proposed methods could successfully identify the motor stator status from normal, to loss of stator winding imminent and arcing, and lastly to open circuit in stator winding—motor needing to stop immediately—by using gathered data from real experiments, training the model and testing it theoretically. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
19961073
Volume :
13
Issue :
4
Database :
Complementary Index
Journal :
Energies (19961073)
Publication Type :
Academic Journal
Accession number :
142199084
Full Text :
https://doi.org/10.3390/en13040820