Back to Search Start Over

Combining Mechanistic Modeling and Raman Spectroscopy for Monitoring Antibody Chromatographic Purification.

Authors :
Feidl, Fabian
Garbellini, Simone
Luna, Martin F.
Vogg, Sebastian
Souquet, Jonathan
Broly, Hervé
Morbidelli, Massimo
Butté, Alessandro
Source :
Processes; Oct2019, Vol. 7 Issue 10, p683-683, 1p
Publication Year :
2019

Abstract

Chromatography is widely used in biotherapeutics manufacturing, and the corresponding underlying mechanisms are well understood. To enable process control and automation, spectroscopic techniques are very convenient as on-line sensors, but their application is often limited by their sensitivity. In this work, we investigate the implementation of Raman spectroscopy to monitor monoclonal antibody (mAb) breakthrough (BT) curves in chromatographic operations with a low titer harvest. A state estimation procedure is developed by combining information coming from a lumped kinetic model (LKM) and a Raman analyzer in the frame of an extended Kalman filter approach (EKF). A comparison with suitable experimental data shows that this approach allows for the obtainment of reliable estimates of antibody concentrations with reduced noise and increased robustness. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
22279717
Volume :
7
Issue :
10
Database :
Complementary Index
Journal :
Processes
Publication Type :
Academic Journal
Accession number :
139692482
Full Text :
https://doi.org/10.3390/pr7100683