Back to Search Start Over

SyMRI detects delayed myelination in preterm neonates.

Authors :
Schmidbauer, Victor
Geisl, Gudrun
Diogo, Mariana
Weber, Michael
Goeral, Katharina
Klebermass-Schrehof, Katrin
Berger, Angelika
Prayer, Daniela
Kasprian, Gregor
Source :
European Radiology; Dec2019, Vol. 29 Issue 12, p7063-7072, 10p, 2 Diagrams, 3 Charts, 2 Graphs
Publication Year :
2019

Abstract

<bold>Objectives: </bold>The software "SyMRI" generates different MR contrasts and characterizes tissue properties based on a single acquisition of a multi-dynamic multi-echo (MDME)-FLAIR sequence. The aim of this study was to assess the applicability of "SyMRI" in the assessment of myelination in preterm and term-born neonates. Furthermore, "SyMRI" was compared with conventional MRI.<bold>Methods: </bold>A total of 30 preterm and term-born neonates were examined at term-equivalent age using a standardized MRI protocol. MDME sequence (acquisition time, 5 min, 24 s)-based post-processing was performed using "SyMRI". Myelination was assessed by scoring seven brain regions on quantitative T1-/T2-maps, generated by "SyMRI" and on standard T1-/T2-weighted images, acquired separately. Analysis of covariance (ANCOVA) (covariate, gestational age (GA) at MRI (GAMRI)) was used for group comparison.<bold>Results: </bold>In 25/30 patients (83.3%) (18 preterm and seven term-born neonates), "SyMRI" acquisitions were successfully performed. "SyMRI"-based myelination scores were significantly lower in preterm compared with term-born neonates (ANCOVA: T1: F(1, 22) = 7.420, p = 0.012; T2: F(1, 22) = 5.658, p = 0.026). "SyMRI"-based myelination scores positively correlated with GAMRI (T1: r = 0.662, n = 25, p ≤ 0.001; T2: r = 0.676, n = 25, p ≤ 0.001). The myelination scores based on standard MRI did not correlate with the GAMRI. No significant differences between preterm and term-born neonates were detectable.<bold>Conclusions: </bold>"SyMRI" is a highly promising MR technique for neonatal brain imaging. "SyMRI" is superior to conventional MR sequences in the visual detection of delayed myelination in preterm neonates.<bold>Key Points: </bold>• By providing multiple MR contrasts, "SyMRI" is a time-saving method in neonatal brain imaging. • Differences concerning the myelination in term-born and preterm infants are visually detectable on T1-/T2-weighted maps generated by "SyMRI". • "SyMRI" allows a faster and more sensitive assessment of myelination compared with standard MR sequences. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09387994
Volume :
29
Issue :
12
Database :
Complementary Index
Journal :
European Radiology
Publication Type :
Academic Journal
Accession number :
139479403
Full Text :
https://doi.org/10.1007/s00330-019-06325-2