Back to Search Start Over

Accuracy of the short-form Montreal Cognitive Assessment: Systematic review and validation.

Authors :
McDicken, Jennifer A.
Elliott, Emma
Blayney, Gareth
Makin, Stephen
Ali, Myzoon
Larner, Andrew J.
Quinn, Terence J.
VISTA-Cognition Collaborators
Source :
International Journal of Geriatric Psychiatry; Oct2019, Vol. 34 Issue 10, p1515-1525, 11p, 1 Diagram, 4 Charts
Publication Year :
2019

Abstract

<bold>Introduction: </bold>Short-form versions of the Montreal Cognitive Assessment (SF-MoCA) are increasingly used to screen for dementia in research and practice. We sought to collate evidence on the accuracy of SF-MoCAs and to externally validate these assessment tools.<bold>Methods: </bold>We performed systematic literature searching across multidisciplinary electronic literature databases, collating information on the content and accuracy of all published SF-MoCAs. We then validated all the SF-MoCAs against clinical diagnosis using independent stroke (n = 787) and memory clinic (n = 410) data sets.<bold>Results: </bold>We identified 13 different SF-MoCAs (21 studies, n = 6477 participants) with differing test content and properties. There was a pattern of high sensitivity across the range of SF-MoCA tests. In the published literature, for detection of post stroke cognitive impairment, median sensitivity across included studies: 0.88 (range: 0.70-1.00); specificity: 0.70 (0.39-0.92). In our independent validation using stroke data, median sensitivity: 0.99 (0.80-1.00); specificity: 0.40 (0.14-0.87). To detect dementia in older adults, median sensitivity: 0.88 (0.62-0.98); median specificity: 0.87 (0.07-0.98) in the literature and median sensitivity: 0.96 (range: 0.72-1.00); median specificity: 0.36 (0.14-0.86) in our validation. Horton's SF-MoCA (delayed recall, serial subtraction, and orientation) had the most favorable properties in stroke (sensitivity: 0.90, specificity: 0.87, positive predictive value [PPV]: 0.55, and negative predictive value [NPV]: 0.93), whereas Cecato's "MoCA reduced" (clock draw, animal naming, delayed recall, and orientation) performed better in the memory clinic (sensitivity: 0.72, specificity: 0.86, PPV: 0.55, and NPV: 0.93).<bold>Conclusions: </bold>There are many published SF-MoCAs. Clinicians and researchers using a SF-MoCA should be explicit about the content. For all SF-MoCA, sensitivity is high and similar to the full scale suggesting potential utility as an initial cognitive screening tool. However, choice of SF-MoCA should be informed by the clinical population to be studied. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
08856230
Volume :
34
Issue :
10
Database :
Complementary Index
Journal :
International Journal of Geriatric Psychiatry
Publication Type :
Academic Journal
Accession number :
138570518
Full Text :
https://doi.org/10.1002/gps.5162