Back to Search Start Over

Safety assessment of a novel C-type natriuretic peptide derivative and the mechanism of bone- and cartilage-specific toxicity.

Authors :
Yotsumoto, Takafumi
Morozumi, Naomi
Nakamura, Ryuichi
Jindo, Toshimasa
Furuya, Mayumi
Abe, Yasuyuki
Nishimura, Tomonari
Maeda, Hiroaki
Ogasawara, Hiroyuki
Minamitake, Yoshiharu
Kangawa, Kenji
Source :
PLoS ONE; 9/11/2019, Vol. 14 Issue 9, p1-13, 13p
Publication Year :
2019

Abstract

ASB20123, a C-type natriuretic peptide/ghrelin chimeric peptide, was designed as a novel peptide and demonstrated full agonistic activity for natriuretic-peptide receptor B and a significantly longer half-life in plasma compared with the native peptide. We researched the toxicological profile of ASB20123, the correlation between the morphological change of the epiphyseal plate and bone and cartilage toxicity, and biomarkers to detect the toxicity. ASB20123 was systemically administered to male and female rats at daily dose levels of 0.5, 1.5, and 5.0 mg/kg/day for 4 weeks. In this study, toxicity was observed as changes related to bone and cartilage tissues, and no other toxicological changes were observed in all animals. Next, ASB20123 was administered to 12-month-old rats with a little epiphyseal plate. The toxic changes related to bone and cartilage tissues were not observed in any animal with a closed epiphyseal plate, indicating that the toxic changes were triggered by the growth-accelerating effect on the bone and cartilage. Furthermore, we searched for the biomarker related to the bone and cartilage toxicity using rats treated with ASB20123 at doses of 0.005, 0.05, 0.5, and 5.0 mg/kg/day for 4 weeks. A close correlation between necrosis/fibrosis in the epiphysis and metaphysis and thickness of the epiphyseal plate in the femur was confirmed in this study. A decrease in the bone mineral density (BMD) of the femur also was associated with the appearance of bone toxicity. These results indicated that the toxicity of ASB20123 was limited to bone- and cartilage-specific changes, and these changes were triggered by an excessive growth accelerating effect. Furthermore, our data suggested that the thickness of the epiphyseal plate and BMD could be reliable biomarkers to predict bone toxicity. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
19326203
Volume :
14
Issue :
9
Database :
Complementary Index
Journal :
PLoS ONE
Publication Type :
Academic Journal
Accession number :
138560262
Full Text :
https://doi.org/10.1371/journal.pone.0218229