Back to Search Start Over

Dosing pole recommendations for lymphatic filariasis elimination: A height-weight quantile regression modeling approach.

Authors :
Goss, Charles W.
O’Brian, Katiuscia
Dubray, Christine
Fischer, Peter U.
Hardy, Myra
Jambulingam, Purushothaman
King, Christopher L.
Laman, Moses
Lemoine, Jean Frantz
Robinson, Leanne J.
Samuela, Josaia
Subramanian, Swaminathan
Supali, Taniawati
Weil, Gary J.
Schechtman, Kenneth B.
Source :
PLoS Neglected Tropical Diseases; 7/17/2019, Vol. 13 Issue 7, p1-20, 20p
Publication Year :
2019

Abstract

Background: The World Health Organization (WHO) currently recommends height or age-based dosing as alternatives to weight-based dosing for mass drug administration lymphatic filariasis (LF) elimination programs. The goals of our study were to compare these alternative dosing strategies to weight-based dosing and to develop and evaluate new height-based dosing pole scenarios. Methodology/Principal findings: Age, height and weight data were collected from >26,000 individuals in five countries during a cluster randomized LF clinical trial. Weight-based dosing for diethylcarbamazine (DEC; 6 mg/kg) and ivermectin (IVM; 200 ug/kg) with tablet numbers derived from a table of weight intervals was treated as the “gold standard” for this study. Following WHO recommended age-based dosing of DEC and height-based dosing of IVM would have resulted in 32% and 27% of individuals receiving treatment doses below those recommended by weight-based dosing for DEC and IVM, respectively. Underdosing would have been especially common in adult males, who tend to have the highest LF prevalence in many endemic areas. We used a 3-step modeling approach to develop and evaluate new dosing pole cutoffs. First, we analyzed the clinical trial data using quantile regression to predict weight from height. We then used weight predictions to develop new dosing pole cutoff values. Finally, we compared different dosing pole cutoffs and age and height-based WHO dosing recommendations to weight-based dosing. We considered hundreds of scenarios including country- and sex-specific dosing poles. A simple dosing pole with a 6-tablet maximum for both DEC and IVM reduced the underdosing rate by 30% and 21%, respectively, and was nearly as effective as more complex pole combinations for reducing underdosing. Conclusions/Significance: Using a novel modeling approach, we developed a simple dosing pole that would markedly reduce underdosing for DEC and IVM in MDA programs compared to current WHO recommended height or age-based dosing. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
19352727
Volume :
13
Issue :
7
Database :
Complementary Index
Journal :
PLoS Neglected Tropical Diseases
Publication Type :
Academic Journal
Accession number :
137529197
Full Text :
https://doi.org/10.1371/journal.pntd.0007541