Back to Search Start Over

Microfluidic droplet liquid reactors for active pharmaceutical ingredient crystallization by diffusion controlled solvent extraction.

Authors :
Tona, Robert M.
McDonald, Thomas A. O.
Akhavein, Nima
Larkin, Jonathan D.
Lai, David
Source :
Lab on a Chip; 6/21/2019, Vol. 19 Issue 12, p2127-2137, 11p
Publication Year :
2019

Abstract

A novel method for crystallization utilizing solvent/antisolvent extraction in microfluidic droplet liquid reactors has been developed for rapid and low-cost screening of crystal polymorphism (i.e. molecular crystallographic arrangement or internal structure) and habit (i.e. crystallographic shape or external structure). The method involves a ternary solvent system consisting of a dispersed phase of two miscible fluids, one in which the active pharmaceutical ingredient (API) is soluble (solvent) and one in which the API is insoluble (antisolvent). The solvent/antisolvent dispersed phase is immiscible with a third continuous phase. Crystallization of an API, GSK1, was controlled within droplets by altering the rate of solvent extraction from droplets into the continuous phase, thereby decreasing API solubility. Crystal size, habit, and population per droplet were directly impacted by the solvent's rate of extraction. Single crystals were grown in individual droplets by slow extraction of solvent into the surrounding continuous phase, which occurs when crystal growth gradually reduces API concentration such that it is maintained within the metastable zone throughout extraction. Rapid extraction of solvent from droplets results in API concentration significantly exceeding its metastable limit, producing a greater number of crystal nuclei compared to slow extraction conditions. When holding constant solubilized API mass per droplet, crystal sizes were larger for slow extraction rates (l = 96.3, w = 16.6 μm) compared to fast extraction rates (l = 48.8, w = 9.5 μm) as a result of crystal growth occurring on fewer crystal nuclei per droplet. Crystal habit can be controlled by adjusting the solvent extraction rate and consequently the saturation, where minimal saturation resulted in a rhombohedral habit and comparatively higher saturation resulted in an acicular habit with a higher aspect ratio. Antisolvents were tested using two hydrophobic APIs demonstrating the method's capability for rapidly identifying favorable crystal morphologies for downstream manufacturability using miniscule amounts of API. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
14730197
Volume :
19
Issue :
12
Database :
Complementary Index
Journal :
Lab on a Chip
Publication Type :
Academic Journal
Accession number :
136954546
Full Text :
https://doi.org/10.1039/c9lc00204a