Back to Search Start Over

Numerical investigation of tip flow dynamics and main flow characteristics with varying tip clearance widths for an axial-flow pump.

Authors :
Shen, Simin
Qian, Zhongdong
Ji, Bin
Agarwal, Ramesh K
Source :
Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power & Energy (Sage Publications, Ltd.); Jun2019, Vol. 233 Issue 4, p476-488, 13p
Publication Year :
2019

Abstract

The effects of varying tip clearance widths on tip flows dynamics and main flows characteristics for an axial-flow pump are studied employing computational fluid dynamics method. An analysis is presented for the distributions of turbulent kinetic energy, mean axial velocity, and mean vorticity magnitude at the specific flow rate of 0.7 Q <subscript> BEP </subscript>, focusing on flow patterns in the tip region with different tip clearance widths and associated flows. From the simulation results we find that the flow structure of tip vortex and its transportation strongly depend on the tip clearance width, especially for the extension of tip leakage vortex, appearance of induced vortex and the area of tip separation vortex. For a small clearance of 0.15 mm at 0.7 Q <subscript> BEP </subscript>, there is no tip separation vortex at the tip. When tip clearance width becomes larger, a tip separation vortex attaches more on the surface of blade tip as well as vortex intensity of tip flows increases. For tip clearances of 0.9 and 1.2 mm, there is a small part of induced vortex near the blade leading edge. Meanwhile, no induced vortex can be captured for tip clearances of 0.15 and 0.45 mm. The relative angle between the blade chord and tip leakage vortex trajectory reduces gradually when tip clearance width increases from 0.45 to 1.2 mm. Additionally, the radial position of tip leakage vortex core moves inwards as tip clearance width increases. Furthermore, a larger tip clearance width has greater effects on the main-stream characteristics especially near the shroud, which is due to more energy being exchanged between tip flows and main flows. At the flow rate 0.7 Q <subscript> BEP </subscript>, both the efficiency and head of the pump reduce with an increasing tip clearance because of greater energy loss. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09576509
Volume :
233
Issue :
4
Database :
Complementary Index
Journal :
Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power & Energy (Sage Publications, Ltd.)
Publication Type :
Academic Journal
Accession number :
136067173
Full Text :
https://doi.org/10.1177/0957650918812541