Difference between two exhaled nitric oxide analyzers, NIOX VERO® electrochemical hand-held analyzer and NOA280i® chemiluminescence stationary analyzer.

Authors :
Tanabe, Yuki
Harada, Norihiro
Ito, Jun
Matsuno, Kei
Takeshige, Tomohito
Harada, Sonoko
Takemasa, Mirano
Kotajima, Masaki
Ishimori, Ayako
Katsura, Yoko
Makino, Fumihiko
Atsuta, Ryo
Takahashi, Kazuhisa
Source :
Journal of Asthma; Feb2019, Vol. 56 Issue 2, p167-172, 6p, 1 Chart, 4 Graphs
Publication Year :
2019

Abstract

Background: Fractional exhaled nitric oxide (FE<subscript>NO</subscript>) is useful for the evaluation of eosinophilic airway inflammation, including that seen in asthma. Although a new electrochemical hand-held FE<subscript>NO</subscript> analyzer, the NIOX VERO<superscript>®</superscript> (Aerocrine AB, Solna, Sweden), is clinically convenient to use, it has not been fully compared with the chemiluminescence stationary electrochemical analyzer NOA280i<superscript>®</superscript> (Sievers Instruments, Boulder, CO, USA) in terms of the level of measured FE<subscript>NO</subscript>. The aim of this study was to determine whether there is a difference between the two analyzers. Methods: The FE<subscript>NO</subscript> levels measured with both NIOX VERO<superscript>®</superscript> and NOA280i<superscript>®</superscript> were evaluated in 1,369 adults at Juntendo University Hospital from May 2016 to October 2016. Results: The median FE<subscript>NO</subscript> level measured with the NIOX VERO<superscript>®</superscript> was significantly lower than that measured with the NOA280i<superscript>®</superscript> (41 ppb, range 5-368 ppb vs. 29 ppb, range 5-251 ppb; p < 0.001). There was a strong positive correlation in the measurement of FE<subscript>NO</subscript> level between the NOA280i<superscript>®</superscript> and the NIOX VERO<superscript>®</superscript> (r = 0.942, p < 0.001). The following conversion equation was calculated: FE<subscript>NO</subscript> (NOA280i<superscript>®</superscript>) = 1.362 (SE, 0.661) + 1.384 (SE, 0.021) × FE<subscript>NO</subscript> (NIOX VERO<superscript>®</superscript>). Conclusions: To our best knowledge, we have provided the first report showing that the measured FE<subscript>NO</subscript> level with the NIOX VERO<superscript>®</superscript> was approximately 30% lower than that with the NOA280i<superscript>®</superscript> and that there was a significant correlation between the measurements of these two devices. The correction equation that we provided may help assess the data obtained by these two analyzers. Abbreviations: ATS American Thoracic Society BMI Body mass index ERS European Respiratory Society FE<subscript>NO</subscript> Fractional exhaled nitric oxide GINA Global Initiative for Asthma NO Nitric oxide ppb Parts per billion ROC Receiver operating characteristic SD Standard deviation [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
02770903
Volume :
56
Issue :
2
Database :
Complementary Index
Journal :
Journal of Asthma
Publication Type :
Academic Journal
Accession number :
135610657
Full Text :
https://doi.org/10.1080/02770903.2018.1439953