Back to Search
Start Over
Chronic Deafness Degrades Temporal Acuity in the Electrically Stimulated Auditory Pathway.
- Source :
- JARO - Journal of the Association for Research in Otolaryngology; Oct2018, Vol. 19 Issue 5, p541-557, 17p
- Publication Year :
- 2018
-
Abstract
- Electrical stimulation of the auditory nerve with a penetrating intraneural (IN) electrode in acutely deafened cats produces much more restricted spread of excitation than is obtained in that preparation with a conventional cochlear implant (CI) as reported by Middlebrooks and Snyder (J Assoc Res Otolaryngol 8:258-279, 2007). That suggests that a future auditory prosthesis employing IN stimulation might offer human patients greater frequency selectivity than is available with a present-day CI. Nevertheless, it is a concern that the electrical field produced by an IN electrode might be too restricted to produce adequate stimulation of the partially depopulated auditory nerve of a deaf patient. We evaluated this by testing responses to IN and CI stimulation in adult-deafened cats. Activation of the auditory pathway was monitored by recording from the central nucleus of the inferior colliculus (ICC). Cats deaf for 153-277 days exhibited a ~ 30 % loss of auditory nerve fibers compared to cats deaf for < 18 h. Contrary to our concern, measures of thresholds and dynamic ranges showed no significant deafness-related impairment of excitation by IN or CN stimulation. Surprisingly, however, temporal acuity decreased dramatically in these adult-deafened cats, as demonstrated by a marked decrease in the maximum rate of electrical cochlear stimulation to which ICC neurons synchronized to IN or CI stimulation. For instance, half of ICC neurons synchronized to IN stimulation up to 203 pulses per second (pps) in acute deafness, whereas that number dropped to 79 pps for chronic deafness. Such a loss of temporal acuity might contribute to the poor sensitivity to temporal fine structure that has been reported in human CI users. Seemingly, the degraded temporal acuity that we observed in cats was even worse than the fine-structure sensitivity of human CI users, suggesting that most patients experience some improvement of temporal acuity resulting from restoration of patterned auditory nerve stimulation by a CI. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 15253961
- Volume :
- 19
- Issue :
- 5
- Database :
- Complementary Index
- Journal :
- JARO - Journal of the Association for Research in Otolaryngology
- Publication Type :
- Academic Journal
- Accession number :
- 132925147
- Full Text :
- https://doi.org/10.1007/s10162-018-0679-3