Back to Search Start Over

Comparative Analysis of Bearing Current in Wind Turbine Generators.

Authors :
Liu, Ruifang
Ma, Xin
Ren, Xuejiao
Cao, Junci
Niu, Shuangxia
Source :
Energies (19961073); May2018, Vol. 11 Issue 5, p1305, 1p, 10 Diagrams, 7 Charts, 3 Graphs
Publication Year :
2018

Abstract

Bearing current problems frequently appear in wind turbine systems, which cause wind turbines the break down and result in very large losses. This paper investigates and compares bearing current problems in three kinds of wind turbine generators, namely doubly-fed induction generator (DFIG), direct-drive permanent magnet synchronous generator (PMSG), and semi-direct-drive PMSG turbines. Common mode voltage (CMV) of converters is introduced firstly. Then stray capacitances of three kinds of generators are calculated and compared through the finite element method. The bearing current equivalent circuits are proposed and simulations of the bearing current are carried out. It is verified that the bearing currents of DFIGs are more serious than the two kinds of PMSG, while common mode current (CMC) of the direct-drive PMSG is much greater than the other two types of wind turbine generators. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
19961073
Volume :
11
Issue :
5
Database :
Complementary Index
Journal :
Energies (19961073)
Publication Type :
Academic Journal
Accession number :
132397231
Full Text :
https://doi.org/10.3390/en11051305