Signal Transmission Links for the Electron Cyclotron Resonance Heating System on J-TEXT.
- Source :
- IEEE Transactions on Plasma Science; May2018, Vol. 46 Issue 5, Part 1, p1344-1349, 6p
- Publication Year :
- 2018
-
Abstract
- Electron cyclotron resonance heating (ECRH) is an important auxiliary heating method which is widely used in magnetic confinement fusion. For the ECRH system on J-TEXT, signals should be transmitted to the control system for monitoring and protection and also to the data acquisition system. Considering the high-voltage and harsh electromagnetic interference environment, reliable fiber-optic transmission links are applied. Transmitted by fiber-optic modules, the response time of digital signals can be less than $1~\mu \text{s}$. According to the ECRH system requirements, two practical analog fiber-optic transmission links based on the voltage-to-frequency and frequency-to-voltage conversion technology have been designed and developed. With IC AD650, the delay time of most analog signals is less than $100~\mu \text{s}$ , and with IC VFC110, critical signal transmission delay can be shortened to $5~\mu \text{s}$. The test results indicate that the designed signal transmission links for ECRH system on J-TEXT are stable and reliable. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 00933813
- Volume :
- 46
- Issue :
- 5, Part 1
- Database :
- Complementary Index
- Journal :
- IEEE Transactions on Plasma Science
- Publication Type :
- Academic Journal
- Accession number :
- 129949650
- Full Text :
- https://doi.org/10.1109/TPS.2018.2789463