Back to Search Start Over

Predicting delivery of a small-for-gestational-age infant and adverse perinatal outcome in women with suspected pre-eclampsia.

Authors :
Griffin, M.
Seed, P. T.
Duckworth, S.
North, R.
Myers, J.
Mackillop, L.
Simpson, N.
Waugh, J.
Anumba, D.
Kenny, L. C.
Redman, C. W. G.
Shennan, A. H.
Chappell, L. C.
Source :
Ultrasound in Obstetrics & Gynecology; Mar2018, Vol. 51 Issue 3, p387-395, 9p
Publication Year :
2018

Abstract

<bold>Objective: </bold>To evaluate the test performance of 47 biomarkers and ultrasound parameters for the prediction of delivery of a small-for-gestational-age (SGA) infant and adverse perinatal outcome in women presenting with suspected pre-eclampsia.<bold>Methods: </bold>This was a prospective, multicenter observational study in which 47 biomarkers and ultrasound parameters were measured in 397 women with a singleton pregnancy presenting with suspected preterm pre-eclampsia between 20 + 0 and 36 + 6 weeks' gestation, with the objective of evaluating them as predictors of subsequent delivery of a SGA infant and adverse perinatal outcome. Women with confirmed pre-eclampsia at enrollment were excluded. Factor analysis and stepwise logistic regression were performed in two prespecified groups stratified according to gestational age at enrollment. The primary outcome was delivery of a SGA infant with a birth weight < 3rd customized centile (SGA-3), and secondary outcomes were a SGA infant with a birth weight < 10th customized centile and adverse perinatal outcome.<bold>Results: </bold>In 274 women presenting at 20 + 0 to 34 + 6 weeks' gestation, 96 (35%) delivered a SGA-3 infant. For prediction of SGA-3, low maternal placental growth factor (PlGF) concentration had a sensitivity of 93% (95% CI, 84-98%) and negative predictive value (NPV) of 90% (95% CI, 76-97%) compared with a sensitivity of 71% (95% CI, 58-82%) and a NPV of 79% (95% CI, 68-87%) for ultrasound parameters (estimated fetal weight or abdominal circumference < 10th centile). No individual biomarker evaluated had a better performance than did PlGF, and marker combinations made only small improvements to the test performance. Similar results were found in 123 women presenting between 35 + 0 and 36 + 6 weeks' gestation.<bold>Conclusion: </bold>In women presenting with suspected preterm pre-eclampsia, measurement of PlGF offers a useful adjunct for identifying those at high risk of delivering a SGA infant, allowing appropriate surveillance and timely intervention. © 2017 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09607692
Volume :
51
Issue :
3
Database :
Complementary Index
Journal :
Ultrasound in Obstetrics & Gynecology
Publication Type :
Academic Journal
Accession number :
128361241
Full Text :
https://doi.org/10.1002/uog.17490