Back to Search Start Over

Comparison of strain imaging techniques in CRT candidates: CMR tagging, CMR feature tracking and speckle tracking echocardiography.

Authors :
van Everdingen, Wouter M.
Zweerink, Alwin
Nijveldt, Robin
Salden, Odette A. E.
Meine, Mathias
Maass, Alexander H.
Vernooy, Kevin
De Lange, Frederik J.
van Rossum, Albert C.
Croisille, Pierre
Clarysse, Patrick
Geelhoed, Bastiaan
Rienstra, Michiel
Van Gelder, Isabelle C.
Vos, Marc A.
Allaart, Cornelis P.
Cramer, Maarten J.
Source :
International Journal of Cardiovascular Imaging; Mar2018, Vol. 34 Issue 3, p443-456, 14p
Publication Year :
2018

Abstract

Parameters using myocardial strain analysis may predict response to cardiac resynchronization therapy (CRT). As the agreement between currently available strain imaging modalities is unknown, three different modalities were compared. Twenty-seven CRT-candidates, prospectively included in the MARC study, underwent cardiac magnetic resonance (CMR) imaging and echocardiographic examination. Left ventricular (LV) circumferential strain was analysed with CMR tagging (CMR-TAG), CMR feature tracking (CMR-FT), and speckle tracking echocardiography (STE). Basic strain values and parameters of dyssynchrony and discoordination obtained with CMR-FT and STE were compared to CMR-TAG. Agreement of CMR-FT and CMR-TAG was overall fair, while agreement between STE and CMR-TAG was often poor. For both comparisons, agreement on discoordination parameters was highest, followed by dyssynchrony and basic strain parameters. For discoordination parameters, agreement on systolic stretch index was highest, with fair intra-class correlation coefficients (ICC) (CMR-FT: 0.58, STE: 0.55). ICC of septal systolic rebound stretch (SRSsept) was poor (CMR-FT: 0.41, STE: 0.30). Internal stretch factor of septal and lateral wall (ISFsep-lat) showed fair ICC values (CMR-FT: 0.53, STE: 0.46), while the ICC of the total LV (ISFLV) was fair for CMR-FT (0.55) and poor for STE (ICC: 0.32). The CURE index had a fair ICC for both comparisons (CMR-FT: 0.49, STE 0.41). Although comparison of STE to CMR-TAG was limited by methodological differences, agreement between CMR-FT and CMR-TAG was overall higher compared to STE and CMR-TAG. CMR-FT is a potential clinical alternative for CMR-TAG and STE, especially in the detection of discoordination in CRT-candidates. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
15695794
Volume :
34
Issue :
3
Database :
Complementary Index
Journal :
International Journal of Cardiovascular Imaging
Publication Type :
Academic Journal
Accession number :
128214537
Full Text :
https://doi.org/10.1007/s10554-017-1253-5