Back to Search Start Over

On Performing of Interference Technique Based on Selfadjusting Zernike Filters (SA-AVT Method) to Investigate Flows and Validate 3D Flow Numerical Simulations.

Authors :
Pavlov, Al. A.
Shevchenko, A. M.
Khotyanovsky, D. V.
Pavlov, A. A.
Shmakov, A. S.
Golubev, M. P.
Source :
AIP Conference Proceedings; 2017, Vol. 1893 Issue 1, p1-5, 5p, 1 Black and White Photograph, 2 Graphs
Publication Year :
2017

Abstract

We present a method for and results of determination of the field of integral density in the structure of flow corresponding to the Mach interaction of shock waves at Mach number M = 3. The optical diagnostics of flow was performed using an interference technique based on self-adjusting Zernike filters (SA-AVT method). Numerical simulations were carried out using the CFS3D program package for solving the Euler and Navier-Stokes equations. Quantitative data on the distribution of integral density on the path of probing radiation in one direction of 3D flow transillumination in the region of Mach interaction of shock waves were obtained for the first time. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0094243X
Volume :
1893
Issue :
1
Database :
Complementary Index
Journal :
AIP Conference Proceedings
Publication Type :
Conference
Accession number :
125912525
Full Text :
https://doi.org/10.1063/1.5007536