Back to Search Start Over

Application of structured illumination to gas phase thermometry using thermographic phosphor particles: a study for averaged imaging.

Authors :
Zentgraf, Florian
Stephan, Michael
Berrocal, Edouard
Albert, Barbara
Böhm, Benjamin
Dreizler, Andreas
Source :
Experiments in Fluids; Jul2017, Vol. 58 Issue 7, p1-15, 15p
Publication Year :
2017

Abstract

Structured laser illumination planar imaging (SLIPI) is combined with gas phase thermometry measurements using thermographic phosphor (TGP) particles. The technique is applied to a heated jet surrounded by a coflow which is operated at ambient temperature. The respective air flows are seeded with a powder of BaMgAlO:Eu (BAM) which is used as temperature-sensitive gas phase tracer. Upon pulsed excitation in the ultraviolet spectral range, the temperature is extracted based on the two-color ratio method combined with SLIPI. The main advantage of applying the SLIPI approach to phosphor thermometry is the reduction of particle-to-particle multiple light scattering and diffuse wall reflections, yielding a more robust calibration procedure as well as improving the measurement accuracy, precision, and sensitivity. For demonstration, this paper focuses on sample-averaged measurements of temperature fields in a jet-in-coflow configuration. Using the conventional approach, which in contrast to SLIPI is based on imaging with an unmodulated laser light sheet, we show that for the present setup typically ~40% of the recorded signal is affected by the contribution of multiply scattered photons. At locations close to walls even up to 75% of the apparent signal is due to diffuse reflection and wall luminescence of BAM sticking at the surface. Those contributions lead to erroneous temperature fields. Using SLIPI, an unbiased two-color ratio field is recovered allowing for two-dimensional mean temperature reconstructions which exhibit a more realistic physical behavior. This is in contrast to results deduced by the conventional approach. Furthermore, using the SLIPI approach it is shown that the temperature sensitivity is enhanced by a factor of up to ~2 at ~270 °C. Finally, an outlook towards instantaneous SLIPI phosphorescence thermometry is provided. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
07234864
Volume :
58
Issue :
7
Database :
Complementary Index
Journal :
Experiments in Fluids
Publication Type :
Academic Journal
Accession number :
123411188
Full Text :
https://doi.org/10.1007/s00348-017-2364-4