Back to Search Start Over

Thoracic CT- MRI coregistration for regional pulmonary structure-function measurements of obstructive lung disease.

Authors :
Guo, Fumin
Svenningsen, Sarah
Kirby, Miranda
Capaldi, Dante PI
Sheikh, Khadija
Fenster, Aaron
Parraga, Grace
Source :
Medical Physics; May2017, Vol. 44 Issue 5, p1718-1733, 16p
Publication Year :
2017

Abstract

Purpose Recent pulmonary imaging research has revealed that in patients with chronic obstructive pulmonary disease ( COPD) and asthma, structural and functional abnormalities are spatially heterogeneous. This novel information may help optimize treatment in individual patients, monitor interventional efficacy, and develop new treatments. Moreover, by automating the measurement of regional biomarkers for the 19 different anatomical lung segments, there is an opportunity to embed imaging biomarkers into clinically acceptable clinical workflows and improve lung disease clinical care. Therefore, to exploit the regional structure-function information provided by thoracic imaging, and as a first step toward this goal, our objective was to develop a fully automated registration pipeline for thoracic x-ray computed tomography ( CT) and inhaled gas functional magnetic resonance imaging ( MRI) whole lung and segmental structure-function biomarkers. Methods Thirty-five patients including 15 severe, poorly controlled asthmatics and 20 COPD patients [classified according to the global initiative for chronic obstructive lung disease ( GOLD) criteria)] provided written informed consent to a study protocol approved by Health Canada and underwent pulmonary function tests, MRI, and CT during a single 2-hour visit. Using this diverse patient dataset, we developed and evaluated a joint deformable registration approach to simultaneously coregister CT with both <superscript>1</superscript>H and <superscript>3</superscript>He MRI by enforcing the similarity of the deformation fields from the two individual registrations. We derived a simpler model that was equivalent to the original challenging optimization problem through variational analysis and the simpler model gave rise to an efficient numerical solver that was parallelized on a graphics processing unit. The coregistered CT-<superscript>3</superscript>He MRI and whole lung/segmental lung masks were used to generate whole lung and segmental <superscript>3</superscript>He MRI ventilation defect percent ( VDP). To estimate fiducial localization reproducibility, a single observer manually identified 109 pairs of CT and <superscript>3</superscript>He MRI fiducials for 35 patient images on five separate occasions and determined the fiducial localization error ( FLE). CT-<superscript>3</superscript>He MRI registration accuracy was evaluated using the target registration error ( TRE). Whole lung VDP generated using the algorithm was compared with VDP generated using a previously validated semiautomated approach and computational efficiency was evaluated using run time. Results In 35 patients including 15 with severe asthma and 20 with COPD, mean forced expiratory volume in 1 s ( FEV<subscript>1</subscript>) was 63±24%<subscript>pred</subscript> and FEV<subscript>1</subscript>/forced vital capacity ( FVC) was 54 ± 17%. FLE was 0.16 mm and 0.34 mm for <superscript>3</superscript>He MRI and CT, respectively. TRE was 4.5 ± 2.0 mm, 4.0 ± 1.7 mm, 4.8 ± 2.3 mm for asthma, COPD GOLD II, and GOLD III groups, respectively, with a mean of 4.4 ± 2.0 mm for the entire dataset. TRE was significantly improved for joint CT-<superscript>1</superscript>H/<superscript>3</superscript>He MRI registration compared with CT-<superscript>1</superscript>H MRI rigid registration ( P < 0.0001). Whole lung VDP generated using the pipeline was not significantly different ( P = 0.37) compared to a semiautomated method with which it was strongly correlated (r = 0.93, P < 0.0001). The fully automated pipeline required 11 ± 0.4 min to generate whole lung and segmental VDP. Conclusions For a diverse group of patients with COPD and asthma, whole lung and segmental VDP was measured using an automated lung image analysis pipeline which provides a way to incorporate lung functional biomarkers into clinical research and patient care. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00942405
Volume :
44
Issue :
5
Database :
Complementary Index
Journal :
Medical Physics
Publication Type :
Academic Journal
Accession number :
122988707
Full Text :
https://doi.org/10.1002/mp.12160