Back to Search Start Over

Pharmaceutical characterization of novel tenofovir liposomal formulations for enhanced oral drug delivery: in vitro pharmaceutics and Caco-2 permeability investigations.

Authors :
Spinks, Crystal B.
Zidan, Ahmed S.
Khan, Mansoor A.
Habib, Muhammad J.
Faustino, Patrick J.
Source :
Clinical Pharmacology; Feb2017, Vol. 9, p29-38, 10p
Publication Year :
2017

Abstract

Tenofovir, currently marketed as the prodrug tenofovir disoproxil fumarate, is used clinically to treat patients with HIV/AIDS. The oral bioavailability of tenofovir is relatively low, limiting its clinical effectiveness. Encapsulation of tenofovir within modified long-circulating liposomes would deliver this hydrophilic anti-HI V drug to the reticuloendothelial system for better therapeutic efficacy. The objectives of the current study were to prepare and pharmaceutically characterize model liposomal tenofovir formulations in an attempt to improve their bioavailability. The entrapment process was performed using film hydration method, and the formulations were characterized in terms of encapsulation efficiency and Caco-2 permeability. An efficient reverse-phase high-performance liquid chromatography method was developed and validated for tenofovir quantitation in both in vitro liposomal formulations and Caco-2 permeability samples. Separation was achieved isocratically on a Waters Symmetry C8 column using 10 mM Na<subscript>2</subscript>PO<subscript>4</subscript>/acetonitrile pH 7.4 (95:5 v/v). The flow rate was 1 mL/min with a 12 min elution time. Injection volume was 10 µL with ultraviolet detection at 270 nm. The method was validated according to United States Pharmacopeial Convention category I requirements. The obtainedresult showed that tenofovir encapsulation within the prepared liposomes was dependent on the employed amount of the positive charge-imparting agent. The obtained results indicated that calibration curves were linear with r² > 0.9995 over the analytical range of 1-10 µg/mL. Inter- and intraday accuracy and precision values ranged from 95% to 101% and 0.3% to 2.6%, respectively. The method was determined to be specific and robust. Regarding the potential of the prepared vectors to potentiate tenofovir permeability through the Caco-2 model, a 10-fold increase in tenofovir apparent permeability was observed compared to its oral solution. In conclusion, this novel and validated method was successfully applied to characterize both in vitro encapsulation efficiency and Caco-2 permeability transport for the pharmaceutical assessment of novel tenofovir formulations. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
11791438
Volume :
9
Database :
Complementary Index
Journal :
Clinical Pharmacology
Publication Type :
Academic Journal
Accession number :
121624105
Full Text :
https://doi.org/10.2147/CPAA.S119875