Back to Search Start Over

Boil-Off Gas Two-Stage Compression and Recondensation Process at a Liquefied Natural Gas Receiving Terminal.

Authors :
Li, Yajun
Wen, Mingyang
Source :
Chemical Engineering & Technology; Jan2017, Vol. 40 Issue 1, p18-27, 10p
Publication Year :
2017

Abstract

Due to ship unloading and the change of downstream gas consumption, the boil-off gas (BOG) and liquefied natural gas outputs fluctuate constantly, causing difficulties in both the design and operation of the BOG handling process. The high energy consumption, instability, and inflexibility of the original process affect the operation cost and running safety of the terminal to a large extent. To address these problems, a two-stage compression and recondensation process is designed and optimized, based on the original one. Compared with the original process through dynamic simulation, the design process has better stability, benefiting from lower operating pressure and smaller fluctuations of both the pressure and the liquid level in the recondenser. In addition, the power and BOG emission are remarkably reduced, which will soon bring great benefit and recovery of investment cost. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09307516
Volume :
40
Issue :
1
Database :
Complementary Index
Journal :
Chemical Engineering & Technology
Publication Type :
Academic Journal
Accession number :
120282670
Full Text :
https://doi.org/10.1002/ceat.201500751