Experimental Optimization of Passive Cooling of a Heat Source Array Flush-Mounted on a Vertical Plate.

Authors :
Baudoin, Antoine
Saury, Didier
Bo Zhu
Boström, Cecilia
Source :
Energies (19961073); Nov2016, Vol. 9 Issue 11, p912, 12p, 4 Diagrams, 1 Chart, 7 Graphs
Publication Year :
2016

Abstract

Heat sources, such as power electronics for offshore power, could be cooled passively-mainly by conduction and natural convection. The obvious advantage of this strategy is its high reliability. However, it must be implemented in an efficient manner (i.e., the area needs to be kept low to limit the construction costs). In this study, the placement of multiple heat sources mounted on a vertical plate was studied experimentally for optimization purposes. We chose a regular distribution, as this is likely to be the preferred choice in the construction process. We found that optimal spacing can be determined for a targeted source density by tuning the vertical and horizontal spacing between the heat sources. The optimal aspect ratio was estimated to be around two. [ABSTRACT FROM AUTHOR]