Back to Search Start Over

Cohort Study Comparing the Berg Balance Scale and the Mini-BESTest in People Who Have Multiple Sclerosis and Are Ambulatory.

Authors :
Ross, Elaine
Purtill, Helen
Uszynski, Marcin
Hayes, Sara
Casey, Blathin
Browne, Catherine
Coote, Susan
Source :
Physical Therapy; Sep2016, Vol. 96 Issue 9, p1448-1455, 8p
Publication Year :
2016

Abstract

Background. The Berg Balance Scale (BBS) is a balance measure commonly used for people with multiple sclerosis (MS). The Mini-BESTest is an alternative based on balance systems. Objective. The study objective was to compare the BBS and the Mini-BESTest for sensitivity to change, likelihood ratios for walking aid use and falls, and associations with clinical variables in people who have MS and are ambulatory. Design. This was a cohort study with measurements before and after exposure to 8 weeks of routine physical therapy intervention. Methods. For 52 participants who had a primary diagnosis of MS and who were indepen- dently mobile, with or without an aid, demographic details and a history of falls and near falls were collected. Participants completed the Mini-BESTest, Multiple Sclerosis Impact Scale-29, Multiple Sclerosis Walking Scale-12, BBS, Modified Fatigue Impact Scale, and Six-Minute Walk Test. Results. No participant started with a baseline Mini-BESTest maximum score of 28, whereas 38.5% (n20) started with a baseline BBS maximum score of 56. Statistically significant changes in the Mini-BESTest score (X=5.31, SD3.5) and the BBS score (X=1.4, SD1.9) were demonstrated. Effect sizes for the Mini-BESTest and the BBS were 0.70 and 0.37, respectively; standard response means for the Mini-BESTest and the BBS were 1.52 and 0.74, respectively. Areas under the receiver operating characteristic curves for the Mini-BESTest and the BBS were 0.88 and 0.77, respectively, for detecting mobility device use and 0.88 and 0.75, respectively, for detecting self-reported near falls. The Mini-BESTest had a higher correlation for each secondary measure than did the BBS. Limitations. This study involved a sample of convenience; 61% of the participants did not use a walking aid. The order of testing was not randomized, and fall status was obtained through retrospective recall. Conclusions. The Mini-BESTest had a lower ceiling effect and higher values on responsiveness tests. These findings suggest that the Mini-BESTest may be better at detecting changes in balance in people who have MS, are ambulatory, and have relatively little walking disability. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00319023
Volume :
96
Issue :
9
Database :
Complementary Index
Journal :
Physical Therapy
Publication Type :
Academic Journal
Accession number :
117831805
Full Text :
https://doi.org/10.2522/ptj.20150416