Back to Search Start Over

Use of Self-Calibration Data for Multifunctional MEMS Sensor Prognostics.

Authors :
Khan, Haroon Ahmed
Tahir, Imran
Richardson, Andrew
Source :
Journal of Microelectromechanical Systems; Aug2016, Vol. 25 Issue 4, p761-769, 9p
Publication Year :
2016

Abstract

This paper proposes a solution to monitor the degradation of a multifunctional microelectromechanical systems (MEMS) sensor (MFS) and to recalibrate the sensor output accordingly. The solution is able to predict the remaining useful life based on the recalibration history. The MFS used is a dual pressure–humidity hybrid sensor where model data have been used to demonstrate the applicability and performance of the proposed method for diagnosis, self-correction, and prognosis. [2015-0316] [ABSTRACT FROM PUBLISHER]

Details

Language :
English
ISSN :
10577157
Volume :
25
Issue :
4
Database :
Complementary Index
Journal :
Journal of Microelectromechanical Systems
Publication Type :
Academic Journal
Accession number :
117145701
Full Text :
https://doi.org/10.1109/JMEMS.2016.2564499