Back to Search Start Over

High-power and Steady-state Operation of ICRF Heating in the Large Helical Device.

Authors :
Mutoh, T.
Seki, T.
Saito, K.
Kasahara, H.
Seki, R.
Kamio, S.
Kumazawa, R.
Kubo, S.
Shimozuma, T.
Yoshimura, Y.
Igami, H.
Takahashi, H.
Ii, T.
Makino, R.
Nagaoka, K.
Nomura, G.
Shinya, T.
Source :
AIP Conference Proceedings; 2015, Vol. 1689 Issue 1, p1-8, 8p, 6 Diagrams, 10 Graphs
Publication Year :
2015

Abstract

Recent progress in an ion cyclotron range of frequencies (ICRF) heating system and experiment results in a Large Helical Device (LHD) are reported. Three kinds of ICRF antenna pairs were installed in the LHD, and the operation power regimes were extended up to 4.5 MW; also, the steady-state operation was extended for more than 45 min in LHD at a MW power level. We studied ICRF heating physics in heliotron configuration using a Hand Shake type (HAS) antenna, Field Aligned Impedance Transforming (FAIT) antenna, and Poloidal Array (PA) antenna, and established the optimum minority-ion heating scenario in an LHD. The FAIT antenna having a novel impedance transformer inside the vacuum chamber could reduce the VSWR and successfully injected a higher power to plasma. We tested the PA antennas completely removing the Faraday-shield pipes to avoid breakdown and to increase the plasma coupling. The heating performance was almost the same as other antennas; however, the heating efficiency was degraded when the gap between the antenna and plasma surface was large. Using these three kinds of antennas, ICRF heating could contribute to raising the plasma beta with the second- and third-harmonic cyclotron heating mode, and also to raising the ion temperature as discharge cleaning tools. In 2014, steady-state operation plasma with a line-averaged electron density of 1.2 x 10<superscript>19</superscript> m<superscript>-3</superscript>, ion and electron temperature of 2 keV, and plasma sustainment time of 48 min was achieved with ICH and ECH heating power of 1.2 MW for majority helium with minority hydrogen. In 2015, the higherpower steady-state operation with a heating power of up to 3 MW was tested with higher density of 3 x 10<superscript>19</superscript> m<superscript>-3</superscript>. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0094243X
Volume :
1689
Issue :
1
Database :
Complementary Index
Journal :
AIP Conference Proceedings
Publication Type :
Conference
Accession number :
111721168
Full Text :
https://doi.org/10.1063/1.4936474