Using an Adenosine Triphosphate Bioluminescent Assay to Determine Effective Antibiotic Combinations against Carbapenem-Resistant Gram Negative Bacteria within 24 Hours.

Authors :
Cai, Yiying
Leck, Hui
Lim, Tze Peng
Teo, Jocelyn
Lee, Winnie
Hsu, Li Yang
Koh, Tse Hsien
Tan, Thuan Tong
Tan, Thean-Yen
Kwa, Andrea Lay-Hoon
Source :
PLoS ONE; 10/13/2015, Vol. 10 Issue 10, p1-15, 15p
Publication Year :
2015

Abstract

Background: Current in vitro combination testing methods involve enumeration by bacterial plating, which is labor-intensive and time-consuming. Measurement of bioluminescence, released when bacterial adenosine triphosphate binds to firefly luciferin-luciferase, has been proposed as a surrogate for bacterial counts. We developed an ATP bioluminescent combination testing assay with a rapid turnaround time of 24h to determine effective antibiotic combinations. Methods: 100 strains of carbapenem-resistant (CR) GNB [30 Acinetobacter baumannii (AB), 30 Pseudomonas aeruginosa (PA) and 40 Klebsiella pneumoniae (KP)] were used. Bacterial suspensions (10<superscript>5</superscript> CFU/ml) were added to 96-well plates containing clinically achievable concentrations of multiple single and two-antibiotic combinations. At 24h, the luminescence intensity of each well was measured. Receiver operator characteristic curves were plotted to determine optimal luminescence threshold (T<subscript>RLU</subscript>) to discriminate between inhibitory/non-inhibitory combinations when compared to viable plating. The unweighted accuracy (UA) [(sensitivity + specificity)/2] of T<subscript>RLU</subscript> values was determined. External validation was further done using 50 additional CR-GNB. Results: Predictive accuracies of T<subscript>RLU</subscript> were high for when all antibiotic combinations and species were collectively analyzed (T<subscript>RLU</subscript> = 0.81, UA = 89%). When individual thresholds for each species were determined, UA remained high. Predictive accuracy was highest for KP (T<subscript>RLU</subscript> = 0.81, UA = 91%), and lowest for AB (T<subscript>RLU</subscript> = 0.83, UA = 87%). Upon external validation, high overall accuracy (91%) was observed. The assay distinguished inhibitory/non-inhibitory combinations with UA of 80%, 94% and 93% for AB, PA and KP respectively. Conclusion: We developed an assay that is robust at identifying useful combinations with a rapid turn-around time of 24h, and may be employed to guide the timely selection of effective antibiotic combinations. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
19326203
Volume :
10
Issue :
10
Database :
Complementary Index
Journal :
PLoS ONE
Publication Type :
Academic Journal
Accession number :
110313027
Full Text :
https://doi.org/10.1371/journal.pone.0140446