Back to Search Start Over

EYE LENS DOSE IN INTERVENTIONAL CARDIOLOGY.

Authors :
Principi, S.
Soler, C. Delgado
Ginjaume, M.
Vilagrasa, M. Beltran
Escutia, J. J. Rovira
Duch, M. A.
Source :
Radiation Protection Dosimetry; Jul2015, Vol. 165 Issue 1-4, p289-293, 5p
Publication Year :
2015

Abstract

The ICRP has recently recommended reducing the occupational exposure dose limit for the lens of the eye to 20 mSv y<superscript>-1</superscript>, averaged over a period of 5 y, with no year exceeding 50 mSv, instead of the current 150 mSv y<superscript>-1</superscript>. This reduction will have important implications for interventional cardiology and radiology (IC/IR) personnel. In this work, lens dose received by a staff working in IC is studied in order to determine whether eye lens dose monitoring or/and additional radiological protection measures are required. Eye lens dose exposure was monitored in 10 physicians and 6 nurses. The major IC procedures performed were coronary angiography and percutaneous transluminal coronary angioplasty. The personnel were provided with two thermoluminescent dosemeters (TLDs): one calibrated in terms of H<subscript>p</subscript>(3) located close to the left ear of the operator and a whole-body dosemeter calibrated in terms of H<subscript>p</subscript>(10) and H<subscript>p</subscript>(0.07) positioned on the lead apron. The estimated annual eye lens dose for physicians ranged between 8 and 60 mSv, for a workload of 200 procedures y<superscript>-1</superscript>. Lower doses were collected for nurses, with estimated annual H<subscript>p</subscript>(3) between 2 and 4 mSv y<superscript>-1</superscript>. It was observed that for nurses the H<subscript>p</subscript>(0.07) measurement on the lead apron is a good estimate of eye lens dose. This is not the case for physicians, where the influence of both the position and use of protective devices such as the ceiling shield is very important and produces large differences among doses both at the eyes and on the thorax. For physicians, a good correlation between H<subscript>p</subscript>(3) and dose area product is shown. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01448420
Volume :
165
Issue :
1-4
Database :
Complementary Index
Journal :
Radiation Protection Dosimetry
Publication Type :
Academic Journal
Accession number :
109177355
Full Text :
https://doi.org/10.1093/rpd/ncv051