Back to Search
Start Over
Individual component analysis of the multi-parametric cardiovascular magnetic resonance protocol in the CE-MARC trial.
- Source :
- Journal of Cardiovascular Magnetic Resonance (Elsevier B.V. ); Jul2015, Vol. 17 Issue 1, p1-9, 9p, 5 Charts, 1 Graph
- Publication Year :
- 2015
-
Abstract
- Background: The CE-MARC study assessed the diagnostic performance investigated the use of cardiovascular magnetic resonance (CMR) in patients with suspected coronary artery disease (CAD). The study used a multi-parametric CMR protocol assessing 4 components: i) left ventricular function; ii) myocardial perfusion; iii) viability (late gadolinium enhancement (LGE)) and iv) coronary magnetic resonance angiography (MRA). In this pre-specified CE-MARC sub-study we assessed the diagnostic accuracy of the individual CMR components and their combinations. Methods: All patients from the CE-MARC population (n = 752) were included using data from the original blinded-read. The four individual core components of the CMR protocol was determined separately and then in paired and triplet combinations. Results were then compared to the full multi-parametric protocol. Results: CMR and X-ray angiography results were available in 676 patients. The maximum sensitivity for the detection of significant CAD by CMR was achieved when all four components were used (86.5 %). Specificity of perfusion (91.8 %), function (93.7 %) and LGE (95.8 %) on its own was significantly better than specificity of the multi-parametric protocol (83.4 %) (all P < 0.0001) but with the penalty of decreased sensitivity (86.5 % vs. 76.9 %, 47.4 % and 40.8 % respectively). The full multi-parametric protocol was the optimum to rule-out significant CAD (Likelihood Ratio negative (LR-) 0.16) and the LGE component alone was the best to rue-in CAD (LR+ 9.81). Overall diagnostic accuracy was similar with the full multi-parametric protocol (85.9 %) compared to paired and triplet combinations. The use of coronary MRA within the full multi-parametric protocol had no additional diagnostic benefit compared to the perfusion/function/LGE combination (overall accuracy 84.6 % vs. 84.2 % (P= 0.5316); LR- 0.16 vs. 0.21; LR+ 5.21 vs. 5.77). Conclusions: From this pre-specified sub-analysis of the CE-MARC study, the full multi-parametric protocol had the highest sensitivity and was the optimal approach to rule-out significant CAD. The LGE component alone was the optimal rule-in strategy. Finally the inclusion of coronary MRA provided no additional benefit when compared to the combination of perfusion/function/LGE. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 1532429X
- Volume :
- 17
- Issue :
- 1
- Database :
- Complementary Index
- Journal :
- Journal of Cardiovascular Magnetic Resonance (Elsevier B.V. )
- Publication Type :
- Academic Journal
- Accession number :
- 108658225
- Full Text :
- https://doi.org/10.1186/s12968-015-0169-2