Back to Search Start Over

Detection of pulmonary emboli with 99mTc-labeled anti-D-dimer (DI-80B3)Fab' fragments (ThromboView).

Authors :
Morris TA
Gerometta M
Yusen RD
White RH
Douketis JD
Kaatz S
Smart RC
Macfarlane D
Ginsberg JS
Morris, Timothy A
Gerometta, Michael
Yusen, Roger D
White, Richard H
Douketis, James D
Kaatz, Scott
Smart, Richard C
Macfarlane, David
Ginsberg, Jeffrey S
Source :
American Journal of Respiratory & Critical Care Medicine; 9/15/2011, Vol. 184 Issue 6, p708-714, 7p
Publication Year :
2011

Abstract

<bold>Rationale: </bold>We report a new method to diagnose acute pulmonary embolism (PE) by single photon emission computerized tomography (SPECT) after administration of (99m)Tc-labeled anti-D-dimer (DI-80B3) monoclonal antibody Fab' fragments. This novel technique provides an additional approach to diagnosing PE in patients for whom other methods are nondiagnostic or contraindicated. <bold>Objectives: </bold>We performed a prospective, multicenter study to investigate the sensitivity and specificity of (99m)Tc-DI-80B3/SPECT in patients with suspected acute PE. <bold>Methods: </bold>Subjects with a moderate to high clinical probability of PE or a positive D-dimer test underwent a PE-protocol contrast-enhanced multidetector thoracic computed tomography (CT) scan as well as (99m)Tc-DI-80B3/SPECT (0.5 mg (99m)Tc-DI-80B3 intravenously followed by a thoracic SPECT 2.5 h later). Separate and independent adjudication committees, blinded to clinical data and other test results, interpreted the (99m)Tc-DI-80B3/SPECT scans (PE detected as foci of abnormally increased (99m)Tc uptake) and the thoracic CT scans using Prospective Investigation of Pulmonary Embolism Diagnosis II criteria. <bold>Measurements and Main Results: </bold>Of the 52 patients who were enrolled and completed both tests, 42 had both evaluable SPECT scans and thoracic CT scans. Using the criterion standard (thoracic CT scan) there were 21 patients with PE and 21 without. (99m)Tc-DI-80B3/SPECT had a sensitivity of 76.2% (95% confidence interval, 52.8-91.8%) and a specificity of 90.5% (95% confidence interval, 69.8-98.8%). Treatment-related serious adverse events did not occur. <bold>Conclusions: </bold>(99m)Tc-DI-80B3/SPECT was sensitive and specific for acute PE in subjects with moderate to high clinical probability of PE or a positive D-dimer test. (99m)Tc-DI-80B3/SPECT demonstrated an acceptable safety profile and avoids exposure to contrast. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
1073449X
Volume :
184
Issue :
6
Database :
Complementary Index
Journal :
American Journal of Respiratory & Critical Care Medicine
Publication Type :
Academic Journal
Accession number :
108213809
Full Text :
https://doi.org/10.1164/rccm.201104-0624OC