Back to Search Start Over

Comparison of angioplasty with infusion of tirofiban or abciximab and with implantation of sirolimus-eluting or uncoated stents for acute myocardial infarction: the MULTISTRATEGY randomized trial.

Authors :
Valgimigli M
Campo G
Percoco G
Bolognese L
Vassanelli C
Colangelo S
de Cesare N
Rodriguez AE
Ferrario M
Moreno R
Piva T
Sheiban I
Pasquetto G
Prati F
Nazzaro MS
Parrinello G
Ferrari R
Multicentre Evaluation of Single High-Dose Bolus Tirofiban vs Abciximab With Sirolimus-Eluting Stent or Bare Metal Stent in Acute Myocardial Infarction Study (MULTISTRATEGY) Investigators
Valgimigli, Marco
Campo, Gianluca
Source :
JAMA: Journal of the American Medical Association; 4/16/2008, Vol. 299 Issue 15, p1788-1799, 12p
Publication Year :
2008

Abstract

<bold>Context: </bold>Abciximab infusion and uncoated-stent implantation is a complementary treatment strategy to reduce major adverse cardiac events in patients undergoing angioplasty for ST-segment elevation myocardial infarction (STEMI). It is uncertain whether there may be similar benefits in replacing abciximab with high-dose bolus tirofiban. Similarly, the use of drug-eluting stents in this patient population is currently discouraged because of conflicting results on efficacy reported in randomized trials and safety concerns reported by registries.<bold>Objective: </bold>To evaluate the effect of high-dose bolus tirofiban and of sirolimus-eluting stents as compared with abciximab infusion and uncoated-stent implantation in patients with STEMI undergoing percutaneous coronary intervention.<bold>Design, Setting, and Patients: </bold>An open-label, 2 x 2 factorial trial of 745 patients presenting with STEMI or new left bundle-branch block at 16 referral centers in Italy, Spain, and Argentina between October 2004 and April 2007.<bold>Interventions: </bold>High-dose bolus tirofiban vs abciximab infusion and sirolimus-eluting stent vs uncoated stent implantation.<bold>Main Outcome Measures: </bold>For drug comparison, at least 50% ST-segment elevation resolution at 90 minutes postintervention with a prespecified noninferiority margin of 9% difference (relative risk, 0.89); for stent comparison, the rate of major adverse cardiac events, defined as the composite of death from any cause, reinfarction, and clinically driven target-vessel revascularization within 8 months.<bold>Results: </bold>ST-segment resolution occurred in 302 of 361 patients (83.6%) who had received abciximab infusion and 308 of 361 (85.3%) who had received tirofiban infusion (relative risk, 1.020; 97.5% confidence interval, 0.958-1.086; P < .001 for noninferiority). Ischemic and hemorrhagic outcomes were similar in the tirofiban and abciximab groups. At 8 months, major adverse cardiac events occurred in 54 patients (14.5%) with uncoated stents and 29 (7.8%) with sirolimus stents (P = .004), predominantly reflecting a reduction of revascularization rates (10.2% vs 3.2%). The incidence of stent thrombosis was similar in the 2 stent groups.<bold>Conclusions: </bold>In patients with STEMI undergoing percutaneous coronary intervention, compared with abciximab, tirofiban therapy was associated with noninferior resolution of ST-segment elevation at 90 minutes following coronary intervention, whereas sirolimus-eluting stent implantation was associated with a significantly lower risk of major adverse cardiac events than uncoated stents within 8 months after intervention.<bold>Trial Registration: </bold>clinicaltrials.gov Identifier: NCT00229515. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00987484
Volume :
299
Issue :
15
Database :
Complementary Index
Journal :
JAMA: Journal of the American Medical Association
Publication Type :
Academic Journal
Accession number :
105905831
Full Text :
https://doi.org/10.1001/jama.299.15.joc80026