Back to Search
Start Over
CT fluoroscopy-guided biopsy of 1,000 pulmonary lesions performed with 20-gauge coaxial cutting needles: diagnostic yield and risk factors for diagnostic failure.
- Source :
- CHEST; Dec2009, Vol. 136 Issue 6, p1612-1617, 6p
- Publication Year :
- 2009
-
Abstract
- <bold>Background: </bold>Although conventional CT scan-guided needle biopsy is an established diagnostic method for pulmonary lesions, few large studies have been conducted on the diagnostic outcomes of CT fluoroscopy-guided lung biopsy. We have conducted a retrospective analysis to evaluate the diagnostic outcomes of 1,000 CT fluoroscopy-guided lung biopsies performed with 20-gauge coaxial cutting needles.<bold>Methods: </bold>We determined the diagnostic yield of CT fluoroscopy-guided lung biopsies performed with 20-gauge coaxial cutting needles for 1,000 lesions in 901 patients. Independent risk factors for diagnostic failure (ie, nondiagnostic, false-positive, and false-negative results) were determined with multivariate logistic regression analysis.<bold>Results: </bold>The biopsy results were nondiagnostic in 0.6% of the lesions (6 of 1,000 lesions). The sensitivity and specificity for the diagnosis of malignancy was 94.2% (741 of 787 lesions) and 99.1% (211 of 213 lesions), respectively; diagnostic accuracy was 95.2% (952 of 1,000 lesions). For lesions measuring <or= 1.0 cm, the diagnostic accuracy was 92.7% (140 of 151 lesions). The significant independent risk factors for diagnostic failure were as follows: the acquisition of two or fewer specimens (odds ratio [OR], 2.43; p = 0.007), lesions in the lower lobe (OR, 2.50; p = 0.003), malignant lesions (OR, 7.16; p = 0.007), and lesions measuring <or= 1.0 cm (OR, 3.85; p = 0.016) and >or= 3.1 cm (OR, 4.32; p = 0.007).<bold>Conclusions: </bold>CT fluoroscopy-guided lung biopsy performed with 20-gauge coaxial cutting needles resulted in a high diagnostic yield, even in the case of small lesions. Factors such as the acquisition of two or fewer specimens, lesions in the lower lobe, malignant lesions, and lesions measuring <or= 1.0 cm or >or= 3.1 cm significantly increased the rate of diagnostic failure. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 00123692
- Volume :
- 136
- Issue :
- 6
- Database :
- Complementary Index
- Journal :
- CHEST
- Publication Type :
- Academic Journal
- Accession number :
- 105261376
- Full Text :
- https://doi.org/10.1378/chest.09-0370