Back to Search Start Over

CT fluoroscopy-guided vertebral augmentation with a radiofrequency-induced, high-viscosity bone cement (StabiliT(®)): technical results and polymethylmethacrylate leakages in 25 patients.

Authors :
Trumm CG
Jakobs TF
Stahl R
Sandner TA
Paprottka PM
Reiser MF
Zech CJ
Hoffmann RT
Trumm, Christoph Gregor
Jakobs, Tobias F
Stahl, Robert
Sandner, Torleif A
Paprottka, Philipp M
Reiser, Maximilian F
Zech, Christoph J
Hoffmann, Ralf-Thorsten
Source :
Skeletal Radiology; Jan2013, Vol. 42 Issue 1, p113-120, 8p
Publication Year :
2013

Abstract

<bold>Objective: </bold>To assess the technical results of CT fluoroscopy-guided, radiofrequency-induced vertebral augmentation (StabiliT®) in terms of vertebral height restoration and polymethylmethacrylate (PMMA) leakages, occurring in 25 individual patients with vertebral compression fractures and osteolysis.<bold>Materials and Methods: </bold>From 07/2010 to 08/2011, 25 patients (16 women, nine men; age 71 ± 14; range 41-89) with painful vertebral compression fractures due to osteoporosis (n = 19), metastases (n = 2) or multiple myeloma (n = 4) underwent vertebral augmentation with a radiofrequency-activated, high-viscosity polymethylmethacrylate (PMMA) bone cement (StabiliT® Vertebral Augmentation system; DFINE Europe GmbH, Mannheim) under local anesthesia. Thirty-four vertebrae (Th5-L5) were treated in 27 sessions under CT fluoroscopy guidance (128-row CT, Somatom Definition AS, Siemens, Erlangen) using a unilateral access and a cavity-creating osteotome prior to remote-controlled, hydraulically driven cement injection. 1/2/3 levels were treated in 21/5/1 session(s). Vertebral height change in the midsagittal plane (anterior, midvertebral, posterior endplate distance) and PMMA leaks were retrospectively evaluated using the postinterventional CT.<bold>Results: </bold>All patients were successfully treated in the first session. Mean (MV ± SD) procedure time and amount of injected PMMA were 56 ± 14 min and 4.5 ± 1.4 ml, respectively. Mean anterior/midvertebral/posterior height gain was +7.1/+9.7/+0.4%. Small local vertebral leaks were observed in 18/34 vertebrae (53%) without any clinical sequelae. No major complications occurred.<bold>Conclusions: </bold>CT fluoroscopy-guided, RF-induced vertebral augmentation with a high-viscosity bone cement (StabiliT®) was safe and technically successful in all patients. Using a hydraulic cement injection technique, a moderate restoration of anterior and midvertebral height was seen while the system was not markedly superior to standard vertebroplasty regarding the frequency of minor asymptomatic PMMA leaks. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03642348
Volume :
42
Issue :
1
Database :
Complementary Index
Journal :
Skeletal Radiology
Publication Type :
Academic Journal
Accession number :
104401474
Full Text :
https://doi.org/10.1007/s00256-012-1386-5