Back to Search
Start Over
Clinical experience of strain imaging using DENSE for detecting infarcted cardiac segments.
- Source :
- Journal of Cardiovascular Magnetic Resonance (Elsevier B.V. ); 2015, Vol. 17 Issue 1, p1-9, 9p, 6 Charts, 4 Graphs
- Publication Year :
- 2015
-
Abstract
- Background: We hypothesised that myocardial deformation determined with magnetic resonance imaging (MRI) will detect myocardial scar. Methods: Displacement Encoding with Stimulated Echoes (DENSE) was used to calculate left ventricular strain in 125 patients (29 women and 96 men) with suspected coronary artery disease. The patients also underwent cine imaging and late gadolinium enhancement. 57 patients had a scar area >1 % in at least one segment, 23 were considered free from coronary artery disease (control group) and 45 had pathological findings but no scar (mixed group). Peak strain was calculated in eight combinations: radial and circumferential strain in transmural, subendocardial and epicardial layers derived from short axis acquisition, and transmural longitudinal and radial strain derived from long axis acquisitions. In addition, the difference between strain in affected segments and reference segments, "differential strain", from the control group was analysed. Results: In receiver-operator-characteristic analysis for the detection of 50 % transmurality, circumferential strain performed best with area-under-curve (AUC) of 0.94. Using a cut-off value of -17 %, sensitivity was 95 % at a specificity of 80 %. AUC did not further improve with differential strain. There were significant differences between the control group and global strain circumferential direction (-17 % versus -12 %) and in the longitudinal direction (-13 % versus -10 %). Interobserver and scan-rescan reproducibility was high with an intraclass correlation coefficient (ICC) >0.93. Conclusions: DENSE-derived circumferential strain may be used for the detection of myocardial segments with >50 % scar area. The repeatability of strain is satisfactory. DENSE-derived global strain agrees with other global measures of left ventricular ejection fraction. [ABSTRACT FROM AUTHOR]
- Subjects :
- ACADEMIC medical centers
CONFIDENCE intervals
CORONARY disease
LEFT heart ventricle
MAGNETIC resonance imaging
MEDICAL cooperation
MYOCARDIAL infarction
MYOCARDIUM
RESEARCH
RESEARCH funding
SCARS
STATISTICS
DATA analysis
INTER-observer reliability
RECEIVER operating characteristic curves
DATA analysis software
DESCRIPTIVE statistics
Subjects
Details
- Language :
- English
- ISSN :
- 1532429X
- Volume :
- 17
- Issue :
- 1
- Database :
- Complementary Index
- Journal :
- Journal of Cardiovascular Magnetic Resonance (Elsevier B.V. )
- Publication Type :
- Academic Journal
- Accession number :
- 103721201
- Full Text :
- https://doi.org/10.1186/s12968-015-0155-8