Back to Search Start Over

Non-randomised comparison of acute and long-term outcomes of robotic versus manual ventricular tachycardia ablation in a single centre ischemic cohort.

Authors :
Luther, Vishal
Jamil-Copley, Shahnaz
Koa-Wing, Michael
Shun-Shin, Matthew
Hayat, Sajat
Linton, Nicholas
Lim, Phang
Whinnett, Zachary
Wright, Ian
Lefroy, David
Peters, Nicholas
Davies, D.
Kanagaratnam, Prapa
Source :
Journal of Interventional Cardiac Electrophysiology; Aug2015, Vol. 43 Issue 2, p175-185, 11p
Publication Year :
2015

Abstract

Introduction: Robotically guided radiofrequency (RF) ablation offers greater catheter stability that may improve lesion depth. We performed a non-randomised comparison of patients undergoing ventricular tachycardia (VT) ablation either manually or robotically using the Hansen Sensei system for recurrent implantable defibrillator (ICD) therapy. Methods: Patients with infarct-related scar underwent VT ablation using the Hansen system to assess feasibility compared with patients undergoing manual VT ablation during a similar time period. Power delivery during robotic ablation was restricted to 30 W at 60 s. VT inducibility was checked at the end of the procedure. Pre-ablation ICD therapy burdens over 6 months were compared with post-ablation therapy averaged to a 6-month period. Results: Twelve consecutive patients who underwent robotic VT ablation were compared to 12 consecutive patients undergoing a manual ablation. Patient demographics and comorbidities were similar in the two groups. A higher proportion of robotic cases were urgent (9/12 (75 %)) vs. manual (4/12 (33 %)) ( p = 0.1). Post-ablation VT stimulation did not induce clinical VT in 11/12 (92 %) in each group. There were no peri-procedural complications related to ablation delivery. Patients were followed up for approximately 2 years. Averaged over 6 months, robotic ICD therapy burdens fell from 32 (5-400) events to 2.5 (0-11) ( p = 0.015). Therapy burden fell from 14 (10-25) to 1 (0-5) ( p = 0.023) in the manual group. There was no difference in long-term outcome ( p = 0.60) and mortality (4/12 (33 %), p = 1.0). Conclusion: Robotically guided VT ablation is both feasible and safe when compared to manual ablation with good acute and long-term outcomes. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
1383875X
Volume :
43
Issue :
2
Database :
Complementary Index
Journal :
Journal of Interventional Cardiac Electrophysiology
Publication Type :
Academic Journal
Accession number :
103548380
Full Text :