Back to Search Start Over

Impact of changing rectal dose volume parameters over time on late rectal and urinary toxicity after high-dose intensity-modulated radiotherapy for prostate cancer: A 10-years single centre experience.

Authors :
Fonteyne, Valérie
Sadeghi, Simin
Ost, Piet
Vanpachtenbeke, Frank
Vuye, Philippe
Lumen, Nicolaas
De Meerleer, Gert
Source :
Acta Oncologica; Jun2015, Vol. 54 Issue 6, p854-861, 8p
Publication Year :
2015

Abstract

Background. External beam radiotherapy is an excellent treatment for patients with prostate cancer (PC). Assessing long-term radiotherapy-induced toxicity is important. We evaluated the impact of implementing different rectal dose volume constraints (DVC) on late rectal and urinary toxicity. Material and methods. Six hundred and thirty-seven PC patients were treated with high-dose intensity-modulated radiotherapy (IMRT) in the primary (median dose of 78 Gy to the prostate) or postoperative setting [median dose of 74 (adjuvant) and 76 Gy (salvage) to the prostatic bed]. Three groups were defined according to different DVC applied over time. The incidence of late rectal and urinary toxicity was evaluated. Three-year actuarial risk estimations of grade 2-3 rectal and urinary toxicity were calculated (Kaplan-Meier statistics). Results. Median follow-up was five years. Overall, the incidence of late grade 3 and 2 rectal toxicity was 1% and 11%. The calculated three-year actuarial risk of developing late grade ≥ 2 rectal toxicity decreased from 16% to 7% and 5% for patients in Group 1, Group 2 and Group 3, respectively (p < 0.001). Respectively, 17 (4%) and 98 (24%) patients developed grade 3 and 2 late urinary toxicity in the primary setting. In the postoperative setting, 15 (6%) and 62 (26%) patients developed grade 3 and 2 urinary toxicity, respectively. The three-year actuarial risk of developing late ≥ grade 2 urinary toxicity in primary- and postoperative-treated patients was 22% and 23%, respectively. This was not significantly different between the three groups. Conclusion. The majority of patients developed no or only moderate rectal toxicity after high-dose IMRT for PC. Implementing different rectal DVC resulted in a significant decrease of late rectal toxicity without affecting urinary toxicity. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0284186X
Volume :
54
Issue :
6
Database :
Complementary Index
Journal :
Acta Oncologica
Publication Type :
Academic Journal
Accession number :
102664803
Full Text :
https://doi.org/10.3109/0284186X.2014.974826