Back to Search
Start Over
Cold experimental study of gas-solid separation of coal gas reburn low NOx burner.
- Source :
- Clean Coal Technology; Mar2014, Vol. 20 Issue 2, p80-83, 4p
- Publication Year :
- 2014
-
Abstract
- Analyse the gas-solid separation efficiency and its influencing factors of coal gas in the technology of partially gasified coal gas reburn to reduce NO<subscript>x</subscript>. Build a gas-solid separation cold test rig of coal gas, which matches with a 130 tons cold hearth, exam the impact of separator wind and carrier gas flow rate on gas-solid separation effect of material in the separation device. The results show that, when the intake flow rate of the bottom inlet v<subscript>1</subscript> is 10 m/s, and the flow velocity of the top inlet v<subscript>2</subscript> is 5 m/s, the separation efficiency of semi-coke is the highest, and the separation efficiency of volatile also achieves greater value, the volatile can be well separated from semi-coke. [ABSTRACT FROM AUTHOR]
Details
- Language :
- Chinese
- ISSN :
- 10066772
- Volume :
- 20
- Issue :
- 2
- Database :
- Complementary Index
- Journal :
- Clean Coal Technology
- Publication Type :
- Academic Journal
- Accession number :
- 100018722
- Full Text :
- https://doi.org/10.13226/j.issn.1006-6772.2014.02.021