Back to Search
Start Over
Levels of cytokines and immune activation markers in plasma in human immunodeficiency virus infection: quality control procedures.
- Source :
-
Clinical and diagnostic laboratory immunology [Clin Diagn Lab Immunol] 1998 Nov; Vol. 5 (6), pp. 755-61. - Publication Year :
- 1998
-
Abstract
- Procedures for quality control (QC) in a laboratory that concentrates on cytokine and soluble marker measurements in biological fluids are outlined. Intra-assay, interassay, and interlaboratory experiences are presented. Plasma and serum beta2-microglobulin (beta2M) and neopterin test data are presented in greatest detail, along with substantial tumor necrosis factor alpha (TNF-alpha), gamma interferon, soluble interleukin-2 receptor-alpha (sIL-2Ralpha), sTNF-RII, IL-4, and IL-6 data. Recommended QC procedures for cytokine and soluble-marker testing include replicate testing of two or more reference samples provided by the kit manufacturer, replicate testing of in-house frozen reference QC samples that represent normal and abnormal analyte contents, retesting 15 to 20% of randomly selected samples, and comparing normal reference ranges each year. Also, eight cytokines and soluble markers were evaluated in human immunodeficiency virus (HIV)-seronegative and HIV-seropositive individuals stratified on the basis of CD4 T-cell numbers. Levels of some but not all cytokines in serum increased in HIV infection. There was a tendency for cytokines to increase with more advanced disease, defined by reduced CD4 T-cell numbers. Cytokine changes did not relate closely to CD4 level, indicating that separate information was provided by the measurements of TNF-alpha, sTNF-RII, sIL-2Ralpha, beta2M, and neopterin. Serum IL-4 and TNF-alpha levels were not increased. The quality of laboratory data can impact on clinical relevance. Interlaboratory comparisons revealed substantial differences at some sites and documented the need for external proficiency-testing quality assurance programs.
- Subjects :
- Biomarkers blood
CD4 Lymphocyte Count
Humans
Immunoenzyme Techniques
Laboratories standards
Quality Control
Radioimmunoassay
Reagent Kits, Diagnostic
Reference Values
Reproducibility of Results
Blood Chemical Analysis standards
Cytokines blood
HIV Infections diagnosis
HIV Infections immunology
Neopterin blood
beta 2-Microglobulin analysis
Subjects
Details
- Language :
- English
- ISSN :
- 1071-412X
- Volume :
- 5
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- Clinical and diagnostic laboratory immunology
- Publication Type :
- Academic Journal
- Accession number :
- 9801330
- Full Text :
- https://doi.org/10.1128/CDLI.5.6.755-761.1998